22
JLA Limited
113375 - 16
Stop the drying cycle, with the flame sensor wire still
removed, restart the drying cycle.
The HSI will turn on, and after a few seconds later the gas
valve will be energized and the HSI will shut off. Ignition
(flame) should be evident for approximately 7-seconds and
then shut off.
The HSI module will attempt to light burner only “once.” If
flame is not reestablished the HSI module will lockout and
the “red” indicator light will flash continuously.
Functional check of the HSI module is complete.
Replace the flame sensor wire from the S2 terminal to the
HSI module.
Phase 7 Non-Coin System Diagnostics
IMPORTANT: You must disconnect and lockout the
electric supply and the gas supply or the steam supply
before any covers or guards are removed from the
machine to allow access for cleaning, adjusting,
installation, or testing of any equipment per OSHA
standards.
All major circuits, including door, microprocessor
temperature sensor, heat and motor circuits are monitored.
The Phase 7 non-coin microprocessor controller (computer)
will inform the user, via the L.E.D. display of certain failure
messages, along with L.E.D. indicators on the input/output
board on the back panel of the front right control door.
Diagnostic (L.E.D. Display) Fault Messages
Outputs: (Green)
FAN
Blower Fan On
FWD
Tumbler Forward
REV
Tumbler Reverse
AIR JET
Air Jet On
HEAT
Front Heat
STEAM
Steam Injection
AUX
S.A.F.E. System
Active On
Inputs: (Red)
FUSE
24 VAC to Board (F2)
LINT
Lint Drawer Closed
MAIN
Main Door Closed
EXHL
Exhaust High Limit
SAIL
Sail Switch
BRHL
Burner High Limit
GAS_V
Gas Valve
ESTOP
Emergency Stop
REV _: This L.E.D. will indicate the status of the Tumbler
Reverse direction output. If the request to tumble the drum
in the Reverse direction is made, then the L.E.D. is ON.
AIR JET _: This L.E.D. will indicate the status of the Air Jet
output. If the request to turn on the Air Jet is made, then the
L.E.D. is ON.
HEAT _: This L.E.D. will indicate the status of the Front Heat
output. If the request to turn on the Front Burner is made,
then the L.E.D. is ON.
STEAM _: This L.E.D. will indicate the status of the Steam
Injection output. If the request to turn on the Steam Injection
is made, then the L.E.D. is ON.
AUX _: This L.E.D. will indicate the status of the S.A.F.E.
system output. If the request to turn on the S.A.F.E. system
is made, then the L.E.D. is ON.
Input/Output Board
Input Description (“Red” L.E.D.)
FUSE _: This L.E.D. will indicate the status of the (F2), which
fuses the 24 VAC supplied to the board.
LINT _: This L.E.D. will indicate the status of the Lint Drawer.
If the drawer is closed, then the L.E.D. is ON.
MAIN _: This L.E.D. will indicate the status of the Front
Doors. If the doors are closed, then the L.E.D. is ON.
EXHL _: This L.E.D. will indicate the status of the Exhaust
Hi-Limit Disk. If the disk is closed (Temperature below 225°
F [107° C]), then the L.E.D. is ON.
SAIL _: This L.E.D. will indicate the status of the Sail Switch.
If the switch is closed, then the L.E.D. is ON.
BRHL _: This L.E.D. will indicate the status of the Burner
Hi-Limit Disk. If the disk is closed (Temperature below 330°
F [166° C]), then the L.E.D. is ON.
GAS_V _: This L.E.D. will indicate the status of the Gas
Valve. If the Gas Valve is open (ON), then the L.E.D. is ON.
ESTOP _: This L.E.D. will indicate the status of the
Emergency Stop Switch. If the Emergency Stop Switch is
open (ON), then the L.E.D. is ON.
Water Information ____________________
Before You Start!
Check Local Codes And Permits
Call your local water company or the proper municipal
authority for information regarding local codes.
IMPORTANT: It is your responsibility to have all plumbing
connections made by a qualified professional to assure
that the plumbing installation is adequate and conforms to
local, state, and federal regulations or codes.
Installation
Requirements
The connection point to the electric water solenoid valve is
a 1/2” M.P.T., the S.A.F.E. system must be supplied with a
minimum water pipe size of 1/2-inch and be provided with
40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure. For use
of optional manual bypass, a second source with the same
piping and pressure requirements is required.
Flexible 1/2 feeds must be provided to avoid damage to
electric water solenoid valve by vibration.
Input/Output Board
Output Description (“Green” L.E.D.)
FAN _: This L.E.D. will indicate the status of the Fan output.
If the request to turn on the Fan (blower) is made, then the
L.E.D. is ON.
FWD _: This L.E.D. will indicate the status of the Tumbler
Forward direction output. If the request to tumble the drum
in the Forward direction is made, then the L.E.D. is ON.
Summary of Contents for D120