background image

 

 

 

 

IV.

 

Operation Instruction

 

The default setting of this device is 9600bps baud rate, 8-n-1 communication mode, no flow 

control, slave device, and matching code is 000000. 

If need to change parameters, user should press the mode switch button to enable the adapter to 

enter the parameter setting state. The two previously blinking indicator lights are off and relevant 

parameters are set through the "AT command", such as the parameters of master/slave device, 

baud rate, remote address, etc. 

If 2pcs adapters need to communicate, user must set one as master device and another as salve 

device. User can tell roles from operation indicator light. 

Note: the parameters are stored in FLASH, so the values of the parameters will remain the same 

even after the power is cut, and will not be lost. 

After parameter modification, short press the mode switch button again to enable the adapter to 

enter data mode. 

The adapter should be in data mode when powered on. For the master device, if the address has 

been memorized, the master device is directly connected to the memory device, which can be 

cleared by the "AT+CLEARADDR" instruction. 

For slave devices, wait to be queried and connected by other devices. 

If the two adapters are connected successfully, the connection status indicator (green light) is off 

and the master/slave mode indicator (red light) remains flashing. At this point, the user device is 

just like a serial port connection, sending and receiving data directly. 

Once the device is connected, our serial port adapter will not be automatically disconnected unless 

the signal is poor or the other party's Bluetooth is actively disconnected, and the connection will 

remain. 

Note: the following frequently asked questions section gives an important supplement to the use of 

the equipment and solutions to the problems that customers usually encounter. Please read this 

section carefully before using. 

 

V.

 

Description of the authentication mode 

The BLE serial port adapter only stores the matching information of one master device at most. 

Therefore, when the authentication function is enabled and matched with the master device (such 

as IOS, Android phone or tablet), the matching connection with the new master device will first 

clear the previous host matching information. Therefore, a rematch is required when the previous 

master device connects to the BLE serial adapter again. 

However, when some master devices (such as IOS Ipad) are connected again, because the 

matching information of the BLE serial port adapter is saved before, the master device does not re-

initiate the match after receiving the BLE serial port adapter re-matching request, which will result 

in authentication failure and thus disconnection. In the case of disconnection, first delete the BLE 

serial port adapter matching information in the Bluetooth option of the master device's system 

settings, and reconnect it again. 

 
 
 
 

Summary of Contents for BLE5.0 Series

Page 1: ...BLE5 0 Serial Adapter User Manual Chongqing Jinou Science Technology Development Co Ltd V1 0_20190505 ...

Page 2: ...http www oemblue com Revision History Revision Revised Contents Reviser V1 0_20180821 Initial version MR V1 0_20190505 Add filter and lasting time in AT INQ command MR ...

Page 3: ...re Password 9 13 Scan Around BLE Device 9 14 Stop Scanning 10 15 Inquire Set Parameters of Connection control 10 16 Set Inquire Scan Parameter 12 17 Set Inquire Broadcasting Interval 12 18 Set Inquire Transmit Power 12 19 Set Inquire BLE Data Communication Service UUID 13 20 Set Inquire BLE Data Communication Characteristic TXDUUID 13 Default value 0000 b351d6d8c7ecbdf0eab1bfc6bcbc 13 This channel...

Page 4: ...Common Questions 19 1 How to send AT command 19 2 How to connect the target Bluetooth device when there are multiple Bluetooth devices around 20 3 2pcs BLE adapters can not connect 20 Web www oemblue com 22 ...

Page 5: ...transmission the handshake protocol and the wake up time account for a lower proportion in the data amount of the entire task and the total duration and the advantage of low power consumption is greatly reduced JINOU serial adapter adopts the low power Bluetooth scheme of TI company and supports the BLE mode Can be used in applications sensitive to power consumption such as consumer health care mo...

Page 6: ...nvironment Operating temperature 0 70 Storage temperature 10 70 Humidity 5 90 no condensation Size 99 L 34 W 17 H mm Note1 Here refer to that data to transmission rate between the two adapters which relate to connection parameters such as different phone and adapter data the rate may be different If need it up to maximum transmission rate please set the baud rate to 230400 Note1 The data transmiss...

Page 7: ...ed equipment 1 pin 9 is VCC pin 5 is GND 6 9VDC 100mA rated current Power Interface 6 VDC 200mA rated current internal positive and external negative The positive and negative poles of the power supply cannot be reversed or the products will be burnt out Indicator Name Description Status Indicator Configuration Mode Off No connection Blink every 1 second Connected Off Operation Indicator Configura...

Page 8: ...ght is off it means that a connection has been established with other Bluetooth devices If it flashes once every 1 second it means no connection has been established When the BLE adapter is working in parameter setting mode the master slave mode indicator light and connection status indicator light extinguished Mode switch button After power on BLE adapter is in data mode master slave mode indicat...

Page 9: ...s flashing At this point the user device is just like a serial port connection sending and receiving data directly Once the device is connected our serial port adapter will not be automatically disconnected unless the signal is poor or the other party s Bluetooth is actively disconnected and the connection will remain Note the following frequently asked questions section gives an important supplem...

Page 10: ... no CTS RTS flow control The following CR LF in tables represent ASCII code of the Enter and line feed Every AT command send to the module needs to end up with the two codes Otherwise the AT commands can not be recognized As for it is use to convenient reading In fact there is no in command ...

Page 11: ...vice and configure a remote address once powered on the adapter will connect the slave device of the address 3 Inquire Set Device Name Command Answer Parameter AT NAME name CR LF CR LF OK CR LF name Device name Default BLE0405C1P AT NAME CR LF CR LF OK CR LF CR LF NAME name CR LF 4 Inquire Local Bluetooth Address Command Answer Parameter AT LADDR CR LF CR LF OK CR LF CR LF LADDR bdaddr CR L F bdad...

Page 12: ...ress Command Answer Parameter AT CLEARADDR CR LF CR LF OK CR LF None 7 Inquire Software Version Command Answer Parameter AT VERSION CR LF CR LF OK CR LF CR LF VERSION ver CR LF ver software version 8 Inquire Set Device Role Command Answer Parameter AT ROLE CR LF CR LF OK CR LF CR LF ROLE role CR LF role device type 0 Slave 1 Master Default 0 AT ROLE role CR LF CR LF OK CR LF 9 Set Inquire Baud Rat...

Page 13: ... use hardware flow control otherwise data loss will occur 11 Set Inquire Authentication Mode Command Answer Parameter AT AUTH enable CR LF CR LF OK CR LF enable 0 No authentication 1 authentication Default 0 AT AUTH CR LF CR LF OK CR LF CR LF AUTH enable CR LF 12 Set Inquire Password Command Answer Parameter AT PASSWORD password CR LF CR LF OK CR LF password range 000000 999999 Default 000000 AT P...

Page 14: ...dom private resolvable 3 Random private non resolvable name Device name possibly empty bctype Broadcast type Please refer to section 7 7 65 2 of Bluetooth technical regulation core_4 4 2 Vol 2 PartE for the meaning of specific broadcast type 0 ADV_IND 1ADV_DIRECT_IND 2 ADV_SCAN_IND 3ADV_NONCONN_IND 4 SACN_RSP bcdata Broadcast data Please refer to section 11 of Vol 3 in the bluetooth technical spec...

Page 15: ...meters of Max min and lcy will affect the power consumption in the equipment connection state and transmit the delay of receiving data In addition Max shall not be less than min timeout must be greater than the effective connection interval that is connection gap 1 latency If the device is a slave device and enable is set whether the parameters can be updated successfully depends on the master dev...

Page 16: ...ime CR LF CR LF OK CR LF interval_time Slave device broadcasting interval Range of value 160 4800 Unit 0 625 ms Default 1600 AT ADVINT CR LF CR LF OK CR LF CR LF ADVINT interval_ti me CR LF This parameter affects the power consumption of the slave device and is invalid for the master device If this parameter is set large the slave device will not be able to be found and connected Please note 18 Se...

Page 17: ...value 0000 b351d6d8c7ecbdf0eab1bfc6bcbc This channel is used by the adapter to send data to the opposing BLE Bluetooth device 21 Set Inquire BLE Data Communication Characteristic RXD UUID Command Answer Parameter AT BLECHARACTERRXD u uid CR LF CR LF OK CR LF uuid support 128bit or 16bit UUID AT BLECHARACTERRXD CR LF CR LF BLECHARACTERRXD uuid CR LF CR LF OK CR LF Default value 0000 b352d6d8c7ecbdf...

Page 18: ...pany to test the sending and receiving of data between mobile phones and BLE serial port adapters 1 The BLE serial port adapter keeps the factory default parameters and connects to PC through the serial port Power on and enable it in the data communication mode 2 Open the nRF Connect software and the phone will search the BLE Bluetooth devices nearby The device name BLE0405C1P will be shown which ...

Page 19: ...15 3 Click CONNECT and the interface will display the list of services included in the adapter after successful connection and the connection status indicator will be extinguished ...

Page 20: ...16 ...

Page 21: ...sends to the master device The default RXD feature value UUID is 0x0000b352 d6d8 c7ec bdf0 eab1bfc6bcbc which is the channel that the master device sends to the adapter 4 Click the NOTIFY button to the right of the TXD feature value to enable the PC serial port to send the data Hello World to the serial port of the adapter and the mobile terminal will receive the data and display it in hexadecimal...

Page 22: ...18 5 Click the Send button on the right of the RXD characteristic value to enter the sending interface and switch the sending data format to TEXT format Enter Hello World and click Send ...

Page 23: ...d as 9600bps 8 n 1 and are independent of the serial port parameters of data communication set by AT command Press the switch button to enable the device to enter the parameter setting state The flashing indicator light is off The serial port should receive OPEN x r n x is the number of devices remembered At this time the instruction can be sent It should be noted that all the instructions end wit...

Page 24: ...ddr addrtype to record this device information The addrtype here needs to be consistent with INQRESULT which is generally 0 Public type Send AT BIND 1 instruction to BIND this device Send AT ROLE 1 to set the master device After exiting the parameter setting mode the serial port adapter will actively connect to the specified Bluetooth device 3 2pcs BLE adapters can not connect Enter the parameter ...

Page 25: ...s uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined turning the equipment off and on t...

Page 26: ... Chongqing Jinou Science Technology Development Co Ltd Add D1 802 Overseas Students Pioneer Park No 71 Kecheng Rd Jiulongpo District Chongqing China Telephone 86 23 86501296 Email market jinoux com Web www oemblue com ...

Reviews: