User manual
JINHAN
JDS6052S
Page 1: ...User manual JINHAN JDS6052S ...
Page 2: ...2 Exterior ...
Page 3: ...illoscope button As shown in the figure below there are 18 oscilloscope buttons in the product CH1 PARM1 CH2 PARM2 TRIG MATH 时基 HORI 菜单 MENU These buttons are menu selection buttons Their specific functions are as follows Click CH1 PARM1 to enter the control interface of CH1 ...
Page 4: ...ition of probe x1 x10 x100 F3 Select the coupling mode of channel 1 as DC or AC Increase the size of the channel 1 unit grid representation 5V 10mV Reduce the size of the channel 1 unit grid representation 5V 10mV Move the channel 1 arrow down Move channel 1 arrow up Click CH1 PARM1 again to enter the parameter display interface of CH1 ...
Page 5: ...1 arrow down Move channel 1 arrow up Description The displayed parameters have maximum minimum duty cycle peak to peak value Click CH2 PARM2 to enter the control interface of CH2 In this interface the following buttons have the following features F1 Control channel 2 is displayed or turned off F2 Select Increase of probe x1 x10 x100 F3 Select the coupling mode of channel 1 as DC or AC Increase the...
Page 6: ...llowing buttons have the following features F1 invalid F2 invalid F3 invalid Increase the size of the channel 2 unit grid representation 5V 10mV Reduce the size of the channel 2 unit grid representation 5V 10mV Move the channel 2 arrow down Move channel 2 arrow up Description The displayed parameters have maximum minimum duty cycle peak to peak value Click the TRIG MATH button to enter the trigger...
Page 7: ... Control the trigger slope to rise or fall F2 Select the trigger source as CH1 or CH2 F3 Select the trigger mode as automatic normal or single Invalid invalid Move the trigger arrow down Move the trigger arrow up Click the TRIG MATH button again to enter the MATH interface ...
Page 8: ...t the function of MATH CH1 CH2 CH1 CH2 or CH2 CH1 F3 Choose whether the display mode is YT mode or XY mode invalid invalid invalid invalid Click the 时基 HORI button to enter the time base control interface In this interface the following buttons have the following features F1 Whether to display the auxiliary ruler line ...
Page 9: ...base arrow to the right Click the 时基 HORI button again to enter the ruler line interface In this interface the following buttons have the following features F1 invalid F2 invalid F3 invalid Ruler 2 moves to the left Ruler 2 moves to the right Ruler 1 moves to the left Ruler 1 moves to the right Description The displayed parameters are the position of the ruler 1 the position of the ruler 2 and the...
Page 10: ...erface the following buttons have the following features F1 Select to store the waveform to A or B F2 Select the stored source as CH1 or CH2 F3 Whether to display the stored waveform invalid invalid invalid invalid Click the 菜单 Menu button a second time to enter the settings interface ...
Page 11: ...lowing features F1 Select backlight brightness F2 Select language type F3 invalid invalid invalid invalid invalid Click the 菜单 MENU button for the third time to enter the setting interface In this interface the following buttons have the following features ...
Page 12: ...f power saving invalid invalid invalid invalid Click the Menu Menu button for the fourth time to enter the settings interface In this interface the following buttons have the following features F1 invalid F2 Enter the screenshot interface F3 Restore factory settings invalid invalid invalid invalid ...
Page 13: ...ace In this interface the following buttons have the following features F1 Oscilloscope self calibration F2 Whether CH2 turns on the inversion F3 Whether CH1 turns on the inversion invalid invalid invalid invalid In the screenshot interface the button functions are as follows ...
Page 14: ...shot function is off pressing the OK button is the function to save the waveform In the off state press the switch button and ok button at the same time the oscilloscope will enter the U disk mode connect the computer with the USB cable to view the screenshot in the U disk button Power on or off 自动 AUTO button Automatic detection of waveforms detection range is 20MHz 50Hz button Stop or start wave...
Page 15: ...l generator button F1 Select frequency function or offset function F2 Select the type of output waveform F3 Select amplitude function or duty cycle function Change the number of the output Change the number of the output Select the number to change Select the number to change Note After setting the parameters you need to confirm the output by pressing OK Firmware upgrade instructions In the off st...
Page 16: ...l CH1 200 MSa s Dual channel CH1 CH2 100 MSa s Bandwidth Single channel 50 M Dual channel 25 M Vertical resolution 8 bits Vertical gear 10 mV 5 V probe x1 100 mV 50 V probe x10 Impedance 1 MΩ 25 pF Coupling DC AC Display mode Y T X Y Input voltage 40 V probe x1 400 V probe x10 Using a high voltage probe the maximum voltage is determined by the quality of the probe Time base range 12 5 ns 5 s 100 m...
Page 17: ...nshot function stand by Mathematical calculation CH1 CH2 CH1 CH2 CH2 CH1 Self calibration stand by Signal generator The number of channels 1 Frequency Sine wave 1 Hz 5 MHz Square wave 1 Hz 1 MHz Positive sawtooth wave 1 Hz 1 MHz Reverse sawtooth 1 Hz 1 MHz Amplitude 100 mV 8 V Offset maximum 0 V 4 V Duty cycle 0 100 ...