JNMP60 / JNMM60

Installation and Maintenance Manual 

for Jinergy Photovoltaic Module

Summary of Contents for JNMM60 series

Page 1: ...晋能清洁能源科技股份公司 2018 12 25 JNMP60 JNMM60 Installation and Maintenance Manual for Jinergy Photovoltaic Module ...

Page 2: ...晋能清洁能源科技股份公司 2 2018 12 25 Content ...

Page 3: ...晋能清洁能源科技股份公司 3 2018 12 25 Module Unit mm Grounding holes Mounting slot Label Front Side Rear Assembly Drawing JNMM60 JNMP60 ...

Page 4: ...份公司 4 2018 12 25 Dimension Of Module 40 feet High Container 1650 992 35 Pcs Pallet 31 Pallet Stack 2 Extra Pcs Stack 4 Stacks Container 14 Pcs Container 924 Unit mm Transportation Packing configuration Extra Pcs ...

Page 5: ... forklift hold up from the long side forklift arm need to beyond the box width 2 Box transportation needs to keep horizontal or tilted to the direction of forklift 3 Box short edge surface requires to smooth and there is no sharply extrude 3 The forklift can loading 2T or more raising the module smoothly pull out and keep slow speed when holding the module 1 If the forklift hold up from the short ...

Page 6: ...晋能清洁能源科技股份公司 6 2018 12 25 Unit mm B 5 1 A 5 1 Unpacking Material of package A B A B ...

Page 7: ...晋能清洁能源科技股份公司 7 2018 12 25 Unpacking Manner of packing Stacked Package Single Package Unit mm Top Package ...

Page 8: ...remove the box cover Operators must wear gloves to prevent scratching of their hands by frame and keep the glass surfaces clear 3 Cut off the inner packing tape 4 1 Two professional people unpacking the module together from back side 2 When take off the last eight modules the outermost module must be slanted to lean on the other modules Unpacking Operating procedure of unpacking ...

Page 9: ...by side and place neatly 2 If there are not flat floor the stacked package must be break down the short part of carton is facing down stand side by side and place neatly The pallet should be pulled firmly as following 3 The module should be protect when raining or wet which wrapped by waterproof It should be protected by waterproof whether above two methods ...

Page 10: ...t 1 The pallet need to put on the flat ground 2 The glass of first module need to face upward it need to face down from second module 3 It can not more than 20 Pcs pallet totally 4 It is forbidden that carry module by cable of junction box 5 The modules should be stacked neatly avoid the glass blasting because of dislocation 6 People can not move the modules with this method 7 It is not allowed tw...

Page 11: ...f dexter picture Color of dexter picture Current of dexter picture 2 If the modules must be gathered together we suggest that the first mix colors secondly mix current mixed power is not recommended 3 Only high current modules can mixed into low current modules series 4 The strapping tape of cable need to use scissors to cut open can t catch the connector pull off ...

Page 12: ...晋能清洁能源科技股份公司 12 2018 12 25 Dimension mm A mm B mm C mm 1650 992 35 1650 200 210 Clamping Installation Installation method Clamp Location ...

Page 13: ... Grounding holes Mounting slot Label 1 The specific way of installation is on the base of EPC 2 The four mounting slots are matched with M8 bolts 3 Put two washer into the bolt on both side of the frame Installation Installation method ...

Page 14: ...ll modules of series connect well 4 Bracket must be checked before the thunderstorm season it is necessary to carry out spot check on underground component if it is ok 5 Jinneng recommend to use the ground cable which radius is 6 mm Recommended grounding way Tooth Gasket Ground Anti thunder Anti thundered measure should be taken to module series Photovoltaic grounding and lightning protection shou...

Page 15: ...e is 1000V 1500V 2 The series quantity of module must be matched with electrical characteristics of inverter 3 It is possible to heat or burn up except for hearing ka when people plug the connector 4 The minimum bended radius is 43mm and prohibit to excessively bend Fail Pass Cable Bending Fail Pass ...

Page 16: ...ng the glass 3 It is not recommended to clean with higher mineral water because there are remaining minerals after dry up 4 It is forbidden to clean with water which temperature is different largely with module otherwise the glass is impossible to broken 5 Clean the water pressure cannot be more than 690 Kpa 6 Do not touch the surface of module with bare hands 7 People can clear it with soft items...

Page 17: ...晋能清洁能源科技股份公司 17 2018 12 25 Maintenance Others The module is forbid to shield by grass droppings and other sundry Otherwise it will cause power decreases serious will cause hot spots combustion ...

Page 18: ...e scratches or glass blowout if glass burst need immediate replacement of module Modules shall not be piled up around flammable items surrounding environment should be good ventilation and heat dissipation In order to keep the system security and work under maximum efficiency electrical and mechanical failure needs to be tested by authorized personnel ...

Page 19: ...t is fixed firmly if not may cause module is overturned by wind Check the grounding line and modules are in good condition Check whether there is cable or other components impact module this phenomenon may cause cell cracked power decreased serious may cause hot spot or burning ...

Page 20: ...any circumstances The module can be installed on roof vehicle and so on which be matched to special bracket Do not pull down anything such as glass label frame and which belong to module Do not paint or paste anything on the surface of module Do not focus the suns ray on the module with burning glass or mirror and so on Please let the child away from module and PV system in the process of transpor...

Page 21: ...tact the module frame rather than grab connector and cable when transfer module Do not tread module in any case To protect the glass is not damaged please do not place heavy objects on the module or throw something which have damage to module Do not clean the module which glass is cracked or cable is damaged Safety Safety ...

Page 22: ...n in the process of operation and it is according to local safety regulations Do not wear metal jewelry in process of installation Please use the insulation of the licensed tools Grounding cables should be properly connected to the the specified location of module frame because there are risk of being struck by lightning To ensure that the grounding resistance must be less than 10Ω Safety Safety ...

Page 23: ... the bracket which avoid loose cable waggle It is forbidden to cable placed on the sharp edges The corresponding protection measures should be made for cable to prevent direct contact with animals Excess gas that battery produced could cause explosion Safety Safety ...

Page 24: ...谢谢观看 THANKS 晋能清洁能源科技股份公司 ...