background image

Crystalline Silicon PV Module

Installation Guide (JET)

Add: No.1 Wenshui Economic Development Zone, Lvliang, Shanxi 032100, China

   

Tel: +86(358)3300916

   

E-mail: [email protected]

   

 

www.jinergy.com

THE FINAL RIGHT OF INTERPRETATION SHALL BE BORNE BY JINERGY.  20171116-D

JINNENG CLEAN ENERGY TECHNOLOGY LTD 

Summary of Contents for JNMM60 series

Page 1: ...uide JET Add No 1 Wenshui Economic Development Zone Lvliang Shanxi 032100 China Tel 86 358 3300916 E mail sales jinergy com www jinergy com THE FINAL RIGHT OF INTERPRETATION SHALL BE BORNE BY JINERGY 20171116 D JINNENG CLEAN ENERGY TECHNOLOGY LTD ...

Page 2: ...stallation Safety 3 Mechanical Installation 3 1 Installation Condition 3 2 Installation Methods 4 Electrical Installation 4 1 Installation 4 2 Grounding 5 Maintenance and Disposal 6 Attachment 6 1 Electricity performance 6 2 List of manufacturers and types of components 3 3 3 3 3 3 4 5 5 5 9 9 10 10 10 10 13 ...

Page 3: ... all safety precautions of all components used in the system 2 1 5 Do not shade portions of the PV module surface from the sun for a long period of time The shaded cell may become hot hot spot phenomenon which can result in solder joints peeling off 2 1 6 Do not clean the glass surface with chemicals 2 1 7 Do not drop the PV module or drop objects onto the PV module 2 1 8 Do not concentrate sunlig...

Page 4: ... maintain the modules Class C fire rating the fire class of the roof and building mate rials should higher than Class C The fire rating of this module is valid only when mounted in the manner specified in the mechanical mounting instructions 3 1 6 Raise the distance when installation requirement is greater than or equal to 0 3 m Mod ule installation use appropriate installation angle refer to the ...

Page 5: ...dule series for clamping with clamps Variable clamping range 4 Electrical Installation Details for wiring in accordance with the NEC and that the grounding method of the frame of arrays shall comply with the NEC Article 250 CNL model instruction manuals shall also incl ude a statement that installation shall be in accordance with CSA C22 1 Safety Standard for Electrical Installations Canadian Elec...

Page 6: ...cial solar cable and plugs for installing the PV system and make sure that all connections are safe and tight The cable cross section size should be 4mm 12AWG and able to withstand the maximum possible system open circuit voltage 4 1 7 Bypass diodes are included in module junction boxes to avoid decreased module perfor mance in the event of shade or shelter Please check the relevant product datash...

Page 7: ... Vmp V Imp A Voc V Isc A Maximum System Voltage VDC Maximum Series Fuse A Dimensions mm STC Weight Kg 1000 15 1650 992 35 40 or 1640 992 35 40 AM 1 5 E 1000W m T 25 18 6 18 9 or 17 6 17 9 JNMP60 240 240 29 34 8 18 36 88 8 77 245 245 29 63 8 27 37 11 8 84 250 250 29 95 8 35 37 33 8 91 255 255 30 26 8 43 37 52 8 98 260 260 30 56 8 51 37 69 9 05 265 265 30 86 8 59 37 89 9 12 270 270 31 15 8 67 38 14 ...

Page 8: ...335 37 88 8 85 46 15 9 31 340 340 38 08 8 93 46 33 9 36 JNMM72 xxx JNMP72 xxx JNMP72 5BB xxx 15SQ045 20SQ045 Jinan JingHeng Electronics Yangzhou Yangjie Electronic Technology Co Ltd ZheJiang ChuangYuan Photovoltaic Technology Co Ltd Jiangsu Jingke New Energy Technology Co Ltd Suzhou Baohing Electric Wire Cable Co Ltd Wuxi Xinghongye Wire Cable Co Ltd ZheJiang ChuangYuan Photovoltaic Technology Co ...