![Jide Nordic Plus 67/60 Manual For Installation, Use And Maintenance Download Page 12](http://html1.mh-extra.com/html/jide/nordic-plus-67-60/nordic-plus-67-60_manual-for-installation-use-and-maintenance_4000641012.webp)
Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 –
NORDIC PLUS (EN) June 2018
12
Combustion
Combustion air
Combustion air is settled by an automatic thermostat, which regulate the working speed of
your fireplace, after started.
Thanks to the temperature sensor (on the right side of the device), the thermostat
automatically settle the coming of air, by opening of closing the air inlet. The thermostat is
not influenced by the room temperature. It only react to the one of the fireplace (which will
depends on the speed of the fans). It is therefore normal that if the temperature of the
fireplace is high, the valve will be closed whatever the control switch and the temperature of
the room are.
To keep this control of your fireplace, it is important to close perfectly the ashtray.
Thermostat is a security and you have to make sure not to provoke any additional air inlet
by letting the ashtray open, which would lead to an overheating causing disused of the
temperature sensor and loss of the guarantee.
Convection air
Originally, your appliance operates with ventilation controlled by a speed controller.
Depending on the chosen position, the speed controller determines the forced hot air flow
outside your fireplace (maximum power heating is reached with ventilation on the highest
level).
The airstat (on the left side of the device) is an accessory which turns on and off ventilation
according to temperature sensor. This ventilation turns on once the fireplace has reached a
certain temperature. Ventilation must always turn when the fireplace is hot, otherwise the
fans will be degraded. Hot air outlet will allow a hot convection air distribution in the room
of the fireplace or in another room. If you have this type of installation, it is essential to take
advice from your approved installer.
There is an option "strop air" which fosters the hot convection air distribution through other
holes, by filling the convection air outlet on the top of the fireplace.
Ashtray
To remove ashes, you have to make a back and forth move, forward to backward with the
pull knob of the grid, when the fire is off.
It is compulsory to empty the ashtray regularly to allow the combustion air flow.