Jetwave TYPHOON G2 Manual Download Page 1

V2.0 - 2022

TYPHOON HOT G2 MANUAL -  WATER JETTER/DRAIN CLEANER

Record Serial Number below and retain product serial number which is 
located on nameplate.

UNIT SERIAL NO.
ENGINE SERIAL NO.
PURCHASE DATE

Hot Water

Petrol Driven

WARNING!

Read this Operator’s Manual 
carefully before using 
this machine. Failure to 
understand and follow the 
contents of this manual may 
result in electrical shock, 
fire and/or serious personal 
injury.

READ CAREFULLY

ENGLISH

VERSION

HOT

WATER JETTING/DRAIN CLEANING MACHINE

®

1300 660 358

Summary of Contents for TYPHOON G2

Page 1: ...IT SERIAL NO ENGINE SERIAL NO PURCHASE DATE Hot Water Petrol Driven WARNING Read this Operator s Manual carefully before using this machine Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury READ CAREFULLY ENGLISH VERSION HOT WATER JETTING DRAIN CLEANING MACHINE 1300 660 358 ...

Page 2: ...Pre Operation Inspection 6 Machine and Work Area Set Up 7 Water Supply 8 Drain Preparation 8 Hose Set Up 8 9 Jetter Hose Selection Chart 10 Jetter Nozzle Selection Chart 10 Operating Instructions 11 13 Jetting the Drain 13 Draining Water from System 13 Using Water Jetter Machine as a Pressure Washer 13 Pressure Washer Operation 13 Machine Shut Down Procedure 14 Hose Reel Brake Adjustment 14 Transp...

Page 3: ... listed below may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS Work Area Safety Keep work area clean and well lit Keep bystanders children and visitors away while operating a water jetter Distractions can cause you to lose control Personal Safety Stay alert watch what you are doing and use common sense when operating a water jetter Do not use a tool while you are tir...

Page 4: ...al protective equipment PPE includes safety glasses and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators head protection hearing protection and steel toed footwear Practice good hygiene Use hot soapy water to wash hands and other body parts exposed to drain contents after handling or using drain cleaning equipment Do not eat ...

Page 5: ...ed to use a combination of water pressure heat and flow to clear grease sludge sediment and roots out of drains A highly flexible and lightweight hose is propelled through the drain pipe by the reverse jets on the jetter nozzle and when retrieved scrubs the line flushing debris away Typhoon Hot G2 Water Jetter equipped with a gasoline engine to drive the triplex plunger pump MODEL PUMP PRESSURE PS...

Page 6: ...half way on sight glasses per Maintenance section Wheels Optional Typically the unit is boxed and shipped with wheels assembled Wheels Axles Locking Collar are found within the box To assemble the wheels slide axles through axle location hole slide wheels on each side find centerline and proceed to install locking collar each side with 4mm Allen key tool if applicable Pre Operation Inspection WARN...

Page 7: ...e and Work Area Set up Always wear safety glasses gloves and other appropriate protective equipment when setting up your jetter to protect against chemicals and bacteria on the equipment Rubber soled non slip shoes can help prevent slipping on wet surfaces Engines produce carbon monoxide a colorless odorless poison gas Breathing carbon monoxide can cause nausea fainting or death Do not start and r...

Page 8: ... Do not use water hotter than 60 C this can cause pump and or float valve damage When using warm water use appropriate personal protective equipment to reduce the risk of burns When using in cold weather use precautions to prevent water from freezing in the pump This can damage the pump Drain Preparation If working through a manhole storm grate or other large access use pipe and fittings to create...

Page 9: ... but should be at least 4 1 2 m 4 Select a nozzle and attach Use nozzles specifically sized for the jetter being used Using incorrect nozzles can cause poor performance low operating pressure or low flow or may damage the jetter with excessively high pressures Make sure the nozzle orifices are clear and open See Jetter Nozzle Selection Chart 5 Many nozzles attach to the hose with a quick connect T...

Page 10: ...n Nozzle hard fixed end within the standard kit for work on smaller diameter pipes 3 to 4 with tighter radiuses bends This nozzle is smaller in size and eliminates the quick connect to allow easier negotiation around bends in the line It has three rear jets with one facing forward for a range of applications Nozzle includes a 1 4 BSPT thread to connect directly to hose thread Small Drain Nozzle su...

Page 11: ...ways includes safety glasses and gloves and may also include equipment such as latex or rubber gloves face shields goggles protective clothing respirators and steel toed footwear Follow operating instructions to reduce the risk of injury from whipping hoses high pressure liquid injection carbon monoxide and other causes 1 Make sure that machine and work area is properly set up and that the work ar...

Page 12: ... the nozzle 6 Assume a proper operating position Be sure you can control the ON OFF action of a water control valve ball valve or foot valve Do not turn the valve ON yet In case of emergency you must be able to turn off water flow Be sure that you have good balance and do not have to overreach You must be able to place one hand on the jetter hose at all times to control and support the hose You mu...

Page 13: ...Jetwave water jetting machine can also be used as a pressure washer Use as a pressure washer is similar to use as a jetter and those instructions should be used in conjunction with the following 1 Locate an appropriate work area 2 Make sure all equipment has been properly inspected 3 Attach the wash wand to the jetter hose using the quick connect coupling Make sure the hose is securely connected t...

Page 14: ...rklift pockets with a forklift Use rigging with current certifications per the manufacturer s instructions Figure 15 Brake Adjustment Maintenance Instructions WARNING Before performing any maintenance engine switch battery isolation switch should be in OFF position and spark plug wires should be disconnected to prevent inadvertent operation Open water control valve to release any fluid pressure in...

Page 15: ...where the temperature is near or below 0 C the jetter must be properly prepared If water freezes in the pump it can damage it After the tank is drained remove the hose from the water inlet filter Open all valves in the system and use compressed air to force any water out of the system This can also be used to remove water from the hoses Service And Repair WARNING Improper service or repair can mak...

Page 16: ...s trapped in system Jetter nozzle orifices are blocked Remove nozzle and insert jet hose in drain line Run jetter to flush trapped air or debris Remove nozzle Use nozzle cleaning tool to clear nozzle orifices push completely through each orifice to remove debris Jetter pressure gauge oscillates from 500 to full operating pressure Jetter nozzle orifices are blocked Debris or air trapped in system R...

Page 17: ...ER DRAIN CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Hour Meter Reading Date Maintenance Performed Service Agent Maintenance Log ...

Page 18: ...18 TYPHOON HOT G2 MANUAL WATER JETTER DRAIN CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Notes ...

Page 19: ...19 TYPHOON HOT G2 MANUAL WATER JETTER DRAIN CLEANER The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement Notes ...

Page 20: ... 3599 sales jetwave com au jetwave com au jetwavegroup jetwave group Copyright Jetwave Group Pty Ltd All Rights Reserved Subject to change without notice The manufacture reserves the right to modify design features and technical facts without notice due to our principals of continuous improvement 1300 660 358 ...

Reviews: