4. Unpacking the box
A. Blower components
Each MJet V3 STD Kit contains the following items:
-
MJet V3 main unit
-
Machine mount
-
Quick Connect
- Pipe
clamps (varying related to order)
-
Cable Seals Kit (varying related to order)
8
5. Set up the blower
This manual contains setup and operating instructions for the MJet V3.
Do not connect air supply until setup is complete.
A. Determine fiber size
• Determine cable size to be installed.
B. Select cable seal & pipe
• Choose the correct cable seal and air block for the particular application according to pipe and cable
size.
C. Install cable seal & cable in air block
• Install the appropriate cable seal on the fiber. Make sure orientation of seal on fiber is correct so
that it will seat in the air block properly. The seal lip of the cable seal should be facing the pipe end.
• Once the cable seal is positioned properly on the cable, install the cable seal in the bottom half
of the appropriate air block.
D. Install pipe
• Place cable seal over the cable.
• Position the pipe properly in the bottom half of the air block.
• Ensure there is adequate length of pipe available to avoid unnecessary strain on the pipe.
• Place cable into pipe, place cable and seal into air block.
• Once the pipe is in place, secure the configuration by installing the top half of the air block and
pressing firmly together.
E. Install pipe & fiber in blower
• Loosen the knob on the air block assembly. Open the air block cover. Insert the pipe into the
air block as shown. Close air block cover and hand tighten knob to secure.