Jetter AG
Parameterization | 8
User Manual – JXM-IO-E30
40 / 70
ID
Dec/Hex
Interface
Parameter
Values
Status
11/b
PWMO_HS7
High-side PWM
output
(up to 7 A)
PWM_FRQ
DITHER_FRQ
DITHER_AMP
MAX_CURRENT
OVERCURRENT_TIME
FILTER_DEEP
MIN_DEVIATION
MIN_CURRENT
OPENCIRCUIT_
DETECTION
I_HCURRENT
O_DUTY_CYCLE
INACTIVE
ERROR
OVERCURRENT
OPEN_CIRCUIT
12/c
DO_HS7
High-side digital
output
(up to 7 A)
MAX_CURRENT
OVERCURRENT_TIME
FILTER_DEEP
MIN_DEVIATION
MIN_CURRENT
OPENCIRCUIT_
DETECTION
I_HCURRENT
O_DIGITAL
INACTIVE
ERROR
OVERCURRENT
OPEN_CIRCUIT
13/d
FI_NPN
Frequency input
(active-low with
pull-up)
SENSOR_SUPPLY
TIMEOUT_TIME
GATE_TIME
I_FREQUENCY
I_DUTY_CYCLE
I_DIGITAL
I_COUNTER
I_PERIODIC_
TIME
I_H_PULSE_TIME
I_L_PULSE_TIME
INACTIVE
ERROR
SUPPLY_FAULT
TIMEOUT
26/1 a
ENCI_PNP
Incremental
encoder input
SENSOR_SUPPLY
TIMEOUT_TIME
RESOLUTION
I_COUNTER
I_DIRECTION
INACTIVE
ERROR
SUPPLY_FAULT
Tab. 32:
Overview – I/O interfaces
8.1.4 Parameters, values and statuses
Input values
Subindex
Description
Type
Types of
access
Unit/
Value range
10
I_VOLTAGE
Voltage value
U16
R
1 mV
11
I_RATIO
Relation to VBAT_ECU
U16
R
1 ‰
12
I_CURRENT
Current value (small measuring
range)
U16
R
1 µA
13
I_HCURRENT
Current value (large measuring
range)
U16
R
1 mA
14
I_FREQUENCY
Frequency value
U32
R
0.1 Hz