![Jetter JVM-507B - HMI User Manual Download Page 63](http://html2.mh-extra.com/html/jetter/jvm-507b-hmi/jvm-507b-hmi_user-manual_3864918063.webp)
Jetter AG
63
JVM-507B
Initial commissioning
Creating and configuring a visualization project in JetSym
The programming tool JetSym STX lets you create visualizations for the HMI
JVM-507B. This topic covers the following:
Creating a project in JetSym STX
Configuring the controller hardware
Including the visualization library JVER-STX
Creating a program that can be compiled and transferred to the HMI
The following requirements must be satisfied:
JetSym has been installed on the PC used.
JetSym has been licensed (see online help in JetSym).
The HMI has been connected to the same network as the PC.
An active Ethernet connection between HMI, and PC has been
established.
Initial commissioning in JetViewSoft has been completed.
To create a new programming project in JetSym, proceed as follows:
Step
Action
1
Launch JetSym
2
Open the menu
File
. Select menu item
New
.
Result:
The dialog box
New
opens.
3
Select
JetSym STX project
as the project type.
4
Enter the project name.
5
Select the path. It is recommended to store project files within a
JetViewSoft project to the folder
STX
.
Example:
C:\Users\xxx\Documents\JetViewSoftProjects\VehicleType_1000\
Visu\VehicleType_1000\VehicleType_1000_Dashboard\STX
Advantage:
The JetSym project files are located in the same folder as the file
VisualInterface.stxp
created by JetViewSoft.
Introduction
Prerequisites
Creating a project