Jetter AG
77
JVM-407B
Mounting and installation of the JVM-407B
Setting the IP address during runtime
The IP interface is initialized by the settings in the configuration memory
during the boot process.
The following settings can also be changed via registers to be non-remanent:
IP address of the HMI
Subnet mask
IP address of default gateway
The settings made during runtime do not change the parameters in the
configuration memory. At de-energizing the controller, your settings will be lost.
Register
Description
104531
IP address of the HMI
104532
Subnet mask
104533
IP address of default gateway
To set the IP address and the subnet mask, proceed as follows:
Step
Action
1
Enter the value 0.0.0.0 into 104533.
2
Enter the value 0.0.0.0 into 104532.
3
Enter the desired IP address of the JVM-407B into 104531.
4
Enter the desired subnet mask into register 104532.
5
Enter the desired IP address of the default gateway into 104533.
Result:
The settings are completed. Communication is possible again.
The configuration memory
(see page 75)
Introduction
Important note
Overview of registers
Setting IP addresses and
subnet mask
Related topics
Summary of Contents for JVM-407B-HMI
Page 1: ...User Manual JVM 407B HMI 60879892 We automate your success...
Page 14: ......
Page 26: ...26 Jetter AG 2 Product description and design Rear view...
Page 34: ......
Page 80: ......
Page 106: ......
Page 144: ......
Page 168: ......
Page 178: ......
Page 182: ......
Page 258: ......
Page 268: ......
Page 274: ......
Page 294: ...294 Jetter AG Appendix Rear view...
Page 299: ......