Jetter AG
295
JVM-407B
Appendix
Operating parameters - Environment and mechanics
Parameter
Description
Operating temperature range
-20 ... +65 °C
Storage temperature range
-30 ... +85 °C
Air humidity
10 ... 95 % (non-condensing)
Do not use a steam jet or other such
devices to clean the JVM-407B.
Climate test
Humid heat
Detailed information on climate test:
Number Temperatur
e (start)
Humidity
(start)
Temperatur
e (end)
Humidity
(end)
Hours
1
23 °C
60 %
23 °C
60 %
1
2
23 °C
0 %
-22 °C
0 %
2
3
-22 °C
0 %
-22 °C
0 %
24
4
-22 °C
0 %
70 °C
20 %
2
5
70 °C
20 %
70 °C
20 %
24
6
70 °C
20 %
70 °C
95 %
1
7
70 °C
95 %
70 °C
95 %
24
8
70 °C
95 %
23 °C
60 %
3
Parameter
Description
Shock resistance
Tested in all three directions
Amplitude of shock: 25 g
Vibration, broadband noise
Complies with DIN EN 60068-2-6, severity
class 2
Degree of protection
Installation directly in console
Front panel: IP64
Rear panel: IP10
Degree of protection
Mounted on support arm
Front panel: IP64
Rear panel: IP64
Environment
Mechanical parameters
Summary of Contents for JVM-407B-HMI
Page 1: ...User Manual JVM 407B HMI 60879892 We automate your success...
Page 14: ......
Page 26: ...26 Jetter AG 2 Product description and design Rear view...
Page 34: ......
Page 80: ......
Page 106: ......
Page 144: ......
Page 168: ......
Page 178: ......
Page 182: ......
Page 258: ......
Page 268: ......
Page 274: ......
Page 294: ...294 Jetter AG Appendix Rear view...
Page 299: ......