Jetter AG
203
JVM-407B
Programming
Ignition and shutdown delay
This chapter covers the ignition and the function
Shutdown ()
.
The special register 361100 of the JVM-407B is responsible for prompting
ignition. Here, the following applies:
If ...
... then ...
Bit 0 = 0:
... ignition is ON and voltage is applied to
terminal 15 IGNITION (+).
Bit 0 = 1:
... ignition is OFF. Ignition is switched off
and no voltage is applied to terminal 15
IGNITION (+).
The HMI has the following default settings in connection with ignition:
If ...
... and ...
... then ...
... voltage is applied to the
HMI, ...
... the ignition is off, ...
... the HMI does not boot up.
... voltage is applied to the
HMI, ...
... the ignition is on, ...
... the HMI boots up.
... the HMI is powered on,
...
... the ignition is switched
off (not the power
supply), ...
... the HMI remains
switched on.
Notwithstanding the default ignition function, the
Shutdown ()
function
provides the following options:
The HMI can be explicitly shut down.
The HMI can be restarted.
Function Shutdown (Reboot:Bool) :Bool;
The
Shutdown ()
function has the following parameters:
Parameter
Description
Value
Reboot
System restart:
System shutdown:
True
False
Introduction
Special registers
Default ignition function
Shutdown () function -
Options
Function declaration
Function parameters
Summary of Contents for JVM-407B-HMI
Page 1: ...User Manual JVM 407B HMI 60879892 We automate your success...
Page 14: ......
Page 26: ...26 Jetter AG 2 Product description and design Rear view...
Page 34: ......
Page 80: ......
Page 106: ......
Page 144: ......
Page 168: ......
Page 178: ......
Page 182: ......
Page 258: ......
Page 268: ......
Page 274: ......
Page 294: ...294 Jetter AG Appendix Rear view...
Page 299: ......