
JetMove 208-480
7.7 Digital Inputs, Logic Power Supply
Jetter AG
71
*)
is connected to the GND of the control system
For connection diagram please refer to “Connection Diagrams” auf Seite 83
INPUT
Digital input
• Depending on the
parameter setting, this
input can be used for
quick stop, position
capture or referencing
without stop.
• DC 24 V
• 7.5 mA max.
• Operating point:
< 6 V low, > 15 V
high
Reference
ground
Ground
*)
for all
inputs and supply of
the logic
Reference
ground
Ground
*)
for all
inputs and supply of
the logic
DC 24 V
Voltage
supply for the
controller
logic
DC 20 ... 30 V
(I < 0.8 A)
BRAKE 1
Braking relay
contact Br1
Relay contact for motor
holding brake
The relay can be operated
either by the control
program or by the firmware
of the JetMove 208-480 at
release of the motor
current.
A free-wheeling diode is
necessary if not integrated
in the motor already.
In Jetter motors, free-
wheeling diodes have not
been integrated!
Recommended diode type:
1N4002
V
max.
= DC 30 V
I
max.
= DC 2 A
Contact: Type NO
These connections
are only for devices
having got the same
reference to ground
as the power supply
of the logic.
BRAKE 2
Braking relay
contact Br1
⊥
⊥
Summary of Contents for JM-208-480-OEM
Page 1: ...User Manual JM 208 480 Digital Servo Amplifier 60870619 We automate your success...
Page 22: ...1 Safety Instructions 22 Jetter AG...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...9 Diagnostics 82 Jetter AG...
Page 86: ...10 Connection Diagrams 86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 208 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...