12.3
Logic Circuit LEDs, Mode Selector
12.3.1 LEDs
The current state of the LED can be queried in register 10182.
.
Note!
If the proper cable is not available, the uplink port of a switch/hub can be used.
The pin assignment of an uplink port allows connection of terminals or can be
switched over.
Some devices are provided with an automatic crossover function which ensures
automatic adjustment to the cable and distant station.
Logic Circuit LEDs
ERR (red LED)
Flashes shortly at initializing.
It remains lit in case of an initialization
error at the Ethernet interface
RUN (green LED)
Flashes regularly at correct functioning
of the Ethernet interface
LED Error Messages
Following power-up the red LED (ERR)
and the green LED (RUN) are flashing
The switch is in LOAD position.
The boot loader is running.
The operating system of the Ethernet
interface is neither being checked, nor
has it been started.
After start-up, the red LED (ERR)
flashes three times, after this, both
LEDs, red (ERR) and green (RUN) are
flashing simultaneously
The switch is in RUN or STOP position.
The boot loader is running.
There is no valid operating system of
the Ethernet interface.
The red LED (ERR) and the green LED
(RUN) are flashing alternately during
runtime
Fatal operating system error of the
Ethernet interface
Summary of Contents for JM-204-480
Page 1: ...User Manual JM 204 480 Digital Servo Amplifier 60870618 We automate your success...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...82 Jetter AG...
Page 86: ...86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 204 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...