JetMove 203B-230
11.1 Function
Jetter AG
87
11
Analog Input (Option)
11.1
Function
For the digital servo amplifier JetMove 204-480, an optional integrated analog input
card can be ordered (article designation of the device: JM-204-480...-IA1). This card
supplies an analog input of a 12-bit resolution. The converted value of the measured
voltage can be read by a register of the JetMove in the PLC program or processed
by the firmware of the JetMove in an additional controller. This way it is possible, for
example, to realize a pressure control loop in which the motor controlled by the
JetMove generates the pressure. In this case, a pressure sensor in the machine
connected to the analog input of the JetMove would deliver the actual pressure value
to the control loop.
11.2
Technical Data
Technical Data for the Analog Input
Connection
SUB-D connector (male) at the device
Voltage range
0 ... 10 V
Input current
max. 1.4 mA
Resolution
12 bits
Value range
0 .. 32767 (resolution in steps of 8)
Electrical isolation
None
Accuracy
Zero error
Gain error
max. ± 5 LSB (± 40 values) corresponds to ± 12.2 mV
max. ±
20 LSB (± 160 values) corresponds to
± 48.8 mV
Summary of Contents for JM-204-480
Page 1: ...User Manual JM 204 480 Digital Servo Amplifier 60870618 We automate your success...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...82 Jetter AG...
Page 86: ...86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 204 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...