JetMove 204-480
9.1 Error Messages
Jetter AG
77
9
Diagnostics
9.1
Error Messages
Note!
In the case of an error message, the letter "F" and two successive numbers
appear on the 7-segment display every second.
Error Message Table JetMove 204-480
Error
number
Error type
Description
Response to
errors
Troubleshooting
F 00
Hardware error
Internal hardware
defect
– Immediate
motor power
disable
– Cut drive controller from
power lines
– Return the amplifier for
repair
F 01
Internal supply
error
One or more power
supply voltages are
beyond their limits.
– Immediate
motor power
disable
– Cut drive controller from
power lines
– Return the amplifier for
repair
F 02
Mains phase
error
Failure of one of
the mains phases.
– Immediate
motor power
disable
– Check fuses and wiring
– Acknowledge the error
F 03
Motor cable
breakage
The motor cable is
broken
Be careful:
The motor cable is
tested when the
drive controller is
enabled for the first
time.
– Immediate
motor power
disable
– Check the motor cable
connections
– Acknowledge the error
F 04
Overvoltage in
the DC link
A DC link voltage
>850 V has been
detected.
– Immediate
motor power
disable
– Check input voltage
supply.
– If the motor is used as
generator, reduce the
regenerating power.
– Acknowledge the error
Summary of Contents for JM-204-480
Page 1: ...User Manual JM 204 480 Digital Servo Amplifier 60870618 We automate your success...
Page 34: ...4 Physical Dimensions 34 Jetter AG...
Page 42: ...5 Technical Data 42 Jetter AG...
Page 82: ...82 Jetter AG...
Page 86: ...86 Jetter AG...
Page 106: ...13 Safe Standstill Option 106 Jetter AG...
Page 116: ...15 Ordering Information 116 Jetter AG...
Page 117: ...JetMove 204 480 Appendices Jetter AG 117 Appendices...
Page 118: ...Appendices 118 Jetter AG...