JetMove 204-480
7.2 Motor Connection
Jetter AG
47
7.2.2
Assignment and specification
Specification of Terminal X62
• 4-pin connector (type Phoenix PC 6 / 4 - ST - 10,16)
• Allowed conductor size: max. 0.5 ... 6 mm
2
(AWG 20 ... 7)
• Torque: 1.2 ... 1.5 Nm (10.6 ... 13.3 lbf-inch)
• Ambient temperature: max. 45 °C
• Field wiring
Specifications of Connecting Cable
• Cable size: min. 4 * 1.0 mm² (AWG 18)
• Material: Copper
• Temperature class: 60 °C
Shielding
• Braided copper shield of 80 % coverage
Connection of the motor to the digital servo amplifier JetMove 204-480 has to be
done following the wiring diagram below. Connection of the brake is optional. In this
case, the wires for the brake have to be at least 300 mm longer than the wires of the
motor.
Fig. 9: Connection of motor lines
If the motor is not equipped
with a free-wheeling diode,
it must be installed here.
Jetter motors do
have a
free-wheeling diode!
Recommended diode type:
1N4002
not
NOTE!
Connect shield
with the
greatest possible surface area
to the metallized
connector housing