5 Technical Data
38
Jetter AG
Note 1!
Active Cooling
:
• The fan is activated at 60 °C and deactivated at 40 °C.
• The temperature limit of the heat sink for overtemperature protection is
dynamically set, depending on the overload limit.
Overload
Fig. 6: Maximum heat sink temperature depending on the motor current
Shutdown threshold for heat sink temperature monitoring
Alarm threshold for heat sink temperature monitoring.
• The duration of operation by maximum motor current is evaluated by a starting
temperature of 45 °C.
Note 2!
A line filter can supply several digital servo amplifiers, as long as I
f
(line filter
current) is greater than the total current required by all connected servo
amplifiers.
120 °C
115 °C
1
2
T
I/I
n
80 °C
75 °C
Danger
DANGER resulting from electric shock!
In order to prevent electric shocks, ground the digital servo amplifier
JetMove 204-480
by all means
via two positions; for this, refer to