7 Description of Connections
JetWeb
52
Jetter AG
7.2.4
Connection assignment of terminal box
*)
alternatively to motor connectors
7.3
Connection of the Resolver
7.3.1
Specification
Specification of the connector for terminal X61 (ENCODER)
• 9-pin male SUB-D connector
• Metallised enclosure
Specification of the resolver cable
• Cable size: 3 * 2 * 0.14 mm² + 2 * 0.5 mm²
2 * 0.5 mm² must be used for the thermal sensor
• Cores have to be shielded and twisted in pairs and must be included in an overall
shielding
• The shield must be connected to the connector housings on both ends of the
cable with the greatest possible surface area.
• Material: Copper
• Temperature class: 60 °C
• Maximum cable length: 50 m
Connection Assignment of Terminal Box
*)
Amplifier terminals
Motor Terminal Box - Terminal Assignment
X62.U2
Pin 1
Phase 1
X62.V2
Pin 2
Phase 2
X62.W2
Pin 3
Phase 3
X62.PE
Pin 4
Protective earth
X10.BRAKE2
Pin 7
Brake +
X10.GND
Pin 8
Brake -