6 Drive Controller Structure
48
Jetter AG
Controller type
Specification
Motor control
(commutation)
Space vector modulation
PWM frequency
16 kHz
Current controller:
– Cycle time
62.5 µs
Speed controller:
– Cycle time
125 µs
– Power supply
adjustable
Position feedback controller:
– Cycle time
250 µs
– Speed pre-control
adjustable
Position setpoint generator:
– Sine-square and linear acceleration/
deceleration ramp
can be parameterized
individually
– Setpoint output cycle (position feedback
controller interpolation)
2 ms
Position sensing:
Resolver:
– Resolution
12 bits per revolution
– Sampling interval
62.5 µs
HIPERFACE encoder
(multi- and single-turn)
:
– Interface
HIPERFACE
– Resolution of absolute position
15 bits per revolution
– Resolution of velocity pickup
20 bits per revolution
– Sampling interval
62.5 µs
Sine-cosine sensor:
– Resolution of absolute position
15 bits per encoder period
– Resolution of velocity pickup
20 bits per encoder period
– Sampling interval
62.5 µs