14 Counting Input (Option)
104
Jetter AG
14.3.3 SSI Cable
SSI Cable
JetMove 2xx
(SUB-D connector X72)
Shielding
Specification
of the Cable
Encoder signal:
5 V differential signal
Maximum cable length:
100 m
Attaching screws must
have a metric thread!
Connect shield with the
greatest possible surface
area!
Use metallized enclosure
only!
Pin
Signal
1
Clock+
2
DATA+
3
Do not connect
4
0 V
5
Voltage supply
5 V, 200 mA max.
6
Clock-
7
DATA -
8
Do not connect
9
Do not connect
Shield