3 Fixed Software Bugs
Writing Commands to the BWU1821
The BWU1821 is a gateway between AS interface and CANopen of the
Bihl+Wiedemann GmbH. It can be directly connected to the Jetter CAN
system bus.
BWU1821
Commands of a length greater than 4 bytes cannot be transmitted to the
BWU1821. The following functions, for example, are affected by this error:
Effects of this Bug
Reading parameters of AS interface slaves according to profile 7.4
Writing parameters to AS interface slaves according to profile 7.4
Reading input data of AS interface slaves according to profile 7.4
...
Writing output data to AS interface slaves according to profile 7.4
The following revisions are affected by this bug:
Affected Revisions
OS revision
JX6-SB(-I)
JC-24x
JM-D203-JC24x
< 2.21.0.00
< 3.26.0.00
< 1.13.0.00
Hardware revision
not relevant
Configuration or operating mode
not relevant
Comment 610
There is no remedy to be applied to the releases concerned.
Remedy / Workaround
Starting from the following revisions this bug has been fixed:
Bug Fix
OS revision
JX6-SB(-I)
JC-24x
JM-D203-JC24x
2.21.0.00
3.26.0.00
1.13.0.00
Hardware revision
not relevant
Configuration or operating mode
not relevant
14
Jetter AG