470
Jetter AG
10 Programming
Registers - Description
When entering values into control registers MR 1 through MR 6, the entire
interface is re-initialized and the transmit and receive buffers are cleared.
Error state
This register displays errors which have been detected on receiving a
character as bit-coded value.
Meaning of the individual bits
Bit 12
Buffer overflow
1 =
Although the receiving buffer is full, one or more characters have
been received
Bit 13
Parity error
1 =
The parity bit of the received character is not correct.
Bit 14
Framing error
1 =
The format of the received character does not match the set
parameters.
Module register properties
Type of access
Read/write (clearing)
Protocol
This register lets you set the protocol which is supported by the OS of the
controller. That is, this register is for defining how the interface is used.
Module register properties
Values
1
System logger
2
User-programmable Interface
3
PcomX
Value after reset
3
Introduction
MR 0
MR 1
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......