Jetter AG
347
JC-120MC
Programming
Setting the length of the input field
The input field length for numerical values is set in MR 2813.
MR 2813 = Number of f sign [+ decimal point]
Example:
Number of figures:
6
Decimal point (MR 2811 = 0):
None
Field length (MR 2813):
7
Field length for UserInput
This module register contains the length of the input field.
Module register properties
Values
1 ... 12
Value after reset
11
Takes effect
At the next STX instruction
UserInput()
Setting the length
MR 2813