166
Jetter AG
8 FTP client
Terminating a connection
Clear all connections which are no longer required as this will reduce PLC
load for managing connections.
Function
FtpDisconnect(FtpConnection:Handle):Int;
Description of the function parameters:
Parameter
Value
Remarks
FtpConnection
Handle
Value returned by the
function
FtpConnect()
The following return values are possible:
Return value
0
Connection terminated and deleted
-1
Invalid handle
-2, -3
Communication error, there is, for example, no response from
FTP server