background image

1

DUNA

MONTAGE- UND BEDIENUNGSANLEITUNG

INSTALLATION AND OPERATING
INSTRUCTIONS
INSTRUCTIONS DE MONTAGE ET MODE
D’EMPLOI

Summary of Contents for DUNA

Page 1: ...1 DUNA MONTAGE UND BEDIENUNGSANLEITUNG INSTALLATION AND OPERATING INSTRUCTIONS INSTRUCTIONS DE MONTAGE ET MODE D EMPLOI...

Page 2: ...from the specialist consultant If contrary to expectations technical defects occur in your unit please contact the customer service de partment or your dealer LIST OF CONTENTS PAGE 1 Safety Instructio...

Page 3: ...h off pump before adjusting angle of nozz le For large area massage reduce the strength to half thrust In order to attach and detach the massage fitting switch off the pump To massage a single part of...

Page 4: ...wn to the fact that the unit may only be operated in the proper manner If it is operated in an improper manner the user must bear sole responsibility In such cases therefore the manufacturer cannot ac...

Page 5: ...Sie das D senmantelgeh use b ndig mit der Beckenwand ein Erh lt das Becken f r eine Folienauskleidung einen Putz oder D mmplattenauftrag so m ssen Sie das D senmantelgeh use um die Putz bzw D mmplat...

Page 6: ...ile 5 cm Fliesenplan Bild 2 Fliesen Sie das D senmantelgeh use bis zu seiner Innenkante Becken mit Folienauskleidung Bild 3 Ordnen Sie Klemmrahmen und die Dichtungen nach Bild 3 an 3 2 Tile plan fig 2...

Page 7: ...egel niveau de l eau water level 31 20 35 opt 25 25 6 3 7 24 0 2 3 5 Luftschlauch Tuyau d aspirationd air Air inlet 8x45 36 0 45 0 9 Leerrohr f r Pneumatikschlauch tube pour tuyau pneumatique protecti...

Page 8: ...If the nozzle wouldn t be steered into several directions you have to put out 1 of the plastic disk 9 5 The face plate 2 will be attract with the 2 Screws 1 easily Installing the pump suction and pre...

Page 9: ...ol wall or in an adjacent room The connection must be effected carefully in accor dance with EN 60335 2 41 Connection to the power supply is effected by means of a 5 x 2 5 mm 3N PE 400V cable or a 4 x...

Page 10: ...served before setting up and operating 4 2 First time operation Before operating local safety requirements must be met and safety precautions must be observed Before operating the unit for the first t...

Page 11: ...the amount of air induced 4 6 Massage Before massage you must definite ly reduce the jet pressure Do not utilize full thrust against soft parts of the body For large area massage reduce the strength t...

Page 12: ...r of water just under the surface is made to flow strongly without excessive effervescence being visible on the water surface 4 8 Winterization If the unit is installed in a pool where there is a dan...

Page 13: ...ungen in cm dimensions in cm mesures en cm Senkschraube vis T F M 6 x 40 screw Senkschraube vis T F M 6 x 25 screw Spannplatte centre de plaque de fixation clamping plate Befestigungsplatte plaque de...

Page 14: ...pump DUNA power 400 V 3N AC 50 Hz 2 5 kW 3 5 kW 230 V single phase 50 Hz 3 2 1 7 kW 5 Motor protection The necessary switching and safety elements are accommodated in the control panel and so there is...

Page 15: ...2 K1 1 2 3 4 5 6 6 5 1 2 PE 1 2 1 2 3 4 1 2 3 4 2 1 1 2 1 3 A1 A2 1 2 A1 A2 3 4 16A 30mA Hauptschalter allpol Trennstelle 4A Die bauseitige Installation ist gem den g ltigen Bestimmungen wie z B DIN V...

Page 16: ...E TERRE PH3 5 6 1 PH3 POMPE 3 PH3 5 PH3 14 A2 SCHEMA DE BRANCHEMENT A REALISER POMPE POMPES 3 5 kW ou 2 5 kW TRIPHASEES 400 VOLTS Alimentation Difff rentiel 30mA 0bligatoire SCHEMA DE BRANCHEMENT A RE...