SLIM CONCEALED DUCT UNITOWNER’S MANUAL
Models: JASA18HP230V1AD JASA24HP230V1AD JASA30HP230V1AD JASA36HP230V1AD JASA42HP230V1AD JASA48HP230V1AD
JET-AIR
Page 1: ...SLIM CONCEALED DUCT UNIT OWNER S MANUAL Models JASA18HP230V1AD JASA24HP230V1AD JASA30HP230V1AD JASA36HP230V1AD JASA42HP230V1AD JASA48HP230V1AD JET AIR...
Page 2: ...ergy Saving Tips 25 Thank you for choosing a Slim Concealed Duct Air Conditioning Heating System You can feel confident in your selection because the same pride in craftsmanship and engineering knowle...
Page 3: ...l mounted wiredTether Controller Like all systems this unit provides quiet comfort and energy efficient heating and cooling For many residential and light commercial applications it is the ideal solut...
Page 4: ...36 000 BtuH 42 42 000 BtuH 48 48 000 BtuH Model Type AC Cooling Only HP Heat Pump HC Heat Cool Example JASA18HP230V1AD UMAT 18 1 A O Series Designation Product Type S System O Outdoor Units H Indoor...
Page 5: ...h could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions w...
Page 6: ...system yourself Incorrect repairs may cause electric shock or fire Contact a qualified service technician for all service requirements Keep combustible materials away from the unit Do not put hands or...
Page 7: ...2 Electric Box 3 Communication Cable 4 Wired Tether Controller 5 Communication Cable 6 Front Panel 7 Service Cover 8 Liquid Pipe 9 Gas Pipe 10 Drain Hose 11 Outdoor Power Supply Outdoor Unit 3 1 Air...
Page 8: ...indoor coil has warmed up to prevent blowing uncomfortable cool air into the room TETHER CONTROLLER The wiredTether Controller mounts to the wall up to 8m from the unit It provides complete control ov...
Page 9: ...NOTE AUTO MODE has fixed setpoints of 20 C heating and 25 C cooling which are not adjustable The system will automatically select heating or cooling to maintain room temperature within this band TIME...
Page 10: ...e system takes corrective action or stops Error codes are shown on the unit display to facilitate easy troubleshooting and repair PRIVACY LOCK MODE The wiredTether Controller has a Privacy Lock The Pr...
Page 11: ...On Off to turn On the unit Press again to turn it Off MODE SETTING When the unit is ON press Mode button to select an operating mode It will change sequentially as shown below Auto Cool Dry Fan Heat O...
Page 12: ...indoor unit It will change sequentially as shown below 11 TEMPERATURE SETTING Press or to increase decrease the setpoint temperature as shown below In Cool Dry Fan or Heat mode the setpoint temperatu...
Page 13: ...nts Timer On Setting Turn the unit Off press theTimer button The OFF icon will flash and the hours will be displayed Set the time period for the unit to remain OFF before turning ON by pressing the or...
Page 14: ...unit to remain ON before turning OFF by pressing the or buttons PressTimer button to confirm and startTimer Off mode F F F F F Turn On the unit and select Heat or Cool mode PressTimer button to selec...
Page 15: ...C After 2 hours the setpoint will increase by 2 C and maintain this setpoint until Sleep Mode is cancelled In Heat Mode The unit will run at current room setpoint for 1 hour After 1 hour the setpoint...
Page 16: ...con is displayed Then press Enter Cancel to confirm To cancel press the Function button to re enter theTurbo setting status then press Enter Cancel Press Enter Cancel to cancel setting F F F F F Turn...
Page 17: ...void mold and mildew growth X Fan Settings Turn the unit On and select Cool or Dry mode Press Function button until X fan icon is displayed and then press Enter Cancel to activate this function F F F...
Page 18: ...the I Feel icon is displayed then press Enter Cancel to activate the function 17 F Turn Unit On Press Function until the I Feel icon is displayed Press Enter Cancel to start I Feel mode To cancel pre...
Page 19: ...eeze Guard Setting In Heat mode press Function until the Freeze Guard icon is displayed Press Enter Cancel button to activate To deactivate press Function to select Freeze Guard setting status Then pr...
Page 20: ...s the Function andTimer buttons simultaneously for 5 seconds until 00 is displayed on the temperature display Press Mode button until 05 is displayed Then press and buttons to select the desired indoo...
Page 21: ...splayed Press and to select the outdoor air damper run time see table below F F F F F F 20 AIR CODE 1 2 3 4 5 6 7 8 9 10 Air Damper 6 ON 12 ON 18 ON 24 ON 30 ON 36 ON 42 ON 48 ON 54 ON 60 ON RunTime 5...
Page 22: ...Lock prevents unauthorized access to the unit controls and prevents tampering with system settings To lock the wiredTether Controller press and buttons simultaneously for 5 seconds and the Lock Icon w...
Page 23: ...ast operating mode Power Failure Standby The system will power up in standby or off mode This is the factory default setting POWER FAILURE MODE SETTINGS To set Power Failure Recovery Mode turn the uni...
Page 24: ...e a stable standing platform CLEANING THE FILTER Never remove the air filter from the unit except for cleaning otherwise it may cause dust or dirt to restrict airflow to the unit When the air conditio...
Page 25: ...ressor Motor Failure IPM ModuleTemperatureToo High HighAmbient LowVoltage or Bad Connections Indoor Fan Stopped or Running too Slow High Pressure LowVoltage or Bad Connections Bad Connection Solenoid...
Page 26: ...up to 15 harder 5 Rearrange the room Furniture that obstructs airflow means you could be heating and cooling the back of a chair or the front of a sofa instead of the actual living space Remove or rea...