5
4.0
Specifications
Model number
JDC-500B
Stock number
414850
Motor and electricals
Motor type
totally enclosed industrial
Horsepower
1/3 HP (0.25 kW)
Motor phase
single
Motor voltage
115V
Cycle
60 Hz
Listed FLA (full load amps)
3.6A
Run capacitor
10
F 350VAC
Motor speed
3,420 RPM
On/off switch
Toggle switch with removable key
Power cord
16AWGx3C, 6 ft., SJT
Power plug
5-15P, 125V/15A, installed
Recommended minimum circuit size
1
15 A
Sound emission without load
2
75 dB at 3 ft.
Impeller
Impeller diameter
8 in. (203 mm)
Impeller type
Radial fin
Impeller material
Steel, non-sparking
Performance
Blower only
Air flow at 4 in.
410 CFM (11.6 cmm)
Air velocity at 4 in.
4,684 FPM (23.8 m/s)
Static pressure loss (WC)
2.13 inH
2
O (54 mmH
2
O)
Maximum static pressure loss (WC)
4.02 inH
2
O (102 mmH
2
O)
Assembled unit
with exhaust
filter installed
Air flow at 3 in.
176 CFM (5.0 cmm)
Air velocity at 3 in.
3,583 FPM (18.2 m/s)
Static pressure loss (WC)
1.18 inH
2
O (30 mmH
2
O)
Maximum static pressure loss (WC)
3.74 inH
2
O (95 mmH
2
O)
Filter
Filter size
11-25/32 x 10-15/32 x 1-13/16 in. (299 x 266 x 30 mm)
Filter frame material
Sheet metal
Filter style
composite (double material)
Filter expanded area
20.28 in
2
Filter inside material
Anti-spark/fireproof (MERV 11)
Filter outside material
Spunbond polyester (MERV 13)
Cabinet
Foot print (W x D)
14-9/32 x 19-5/8 in. (363 x 499 mm)
Inlet port diameter
3 in. (76 mm)
Sheet metal thickness
18 ga. (1.2 mm)
Drawer capacity
14.65 in
3
(2.4 L)
Dimensions
Assembled dimensions (W x D x H)
14-9/2 x 19-5/8 x 16-15/16 in. (363 x 499 x 430 mm)
Shipping dimensions L x W x H
22-5/8 x 14-9/16 x 19-1/2 in. (575 x 370 x 495 mm)
Weights
Net weight
49 lb. (22.2 kg)
Shipping weight
53 lb. (24 kg)
1
Subject to local/national electrical codes.
2
The specified values are emission levels and are not necessarily to be seen as safe operating levels. As workplace
conditions vary, this information is intended to allow the user to make a better estimation of the hazards and risks
involved only.