background image

 

 

 

Fig 11 

Note: make sure the bag is fastened 
securely so that no dust will escape 
during operation. 

Attach the hose: 

Use one hose clamp (P) to connect the 
hose (O) to the intake port( Fig 12). 

 

Fig 12 

 

5.2 Dust  connection 

The hose or ductwork you use to 
connect the tool to the dust collector 
must be grounded for avoiding 
explosion. 
(JET Dust Collector Grounding Kit, 
Article Number: JW1053). 

 

5.3 Mains connection 

 

Mains connection and any extension 
cords used must comply with 
applicable regulations. 
The mains voltage must comply with 
the information on the machine licence 
plate.  

The mains connection must have a  
10 A surge-proof fuse. 

Only use power cords marked H07RN-

Connections and repairs to the 
electrical equipment may only be 
carried out by qualified electricians.  

6.  Machine operation 

You can start and stop the machine 
with the magnetic switch (R).Machine 
Plug(400V) is part(T). Fig 13  

              

Fig 13 

7. Maintenance and inspection 

General notes: 
Maintenance, cleaning and repair 
work may only be carried out after 
the machine is protected against 
accidental starting by pulling the 
mains plug. 

Inspect the proper function of the dust 
collection system daily. 

Clean the unit regularly. 

Defective safety devices must be 
replaced immediately. 

Repair and maintenance work on the 
electrical system may only be carried 
out by a qualified electrician. 

 

7.1 Cleaning Filters 

Shake the filter bag whenever it is 
clogged and before each collector bag 
change. 

When the air flow reduces the filter 
must be cleaned. 

To clean the filter on DC-1200CK-M/T, 
turn the handle (I, Fig 10A) a couple of 
rotations so the dust falls into the 
collector bag. 

ATTENTION: 

During the changing or cleaning of the 
filters it’s necessary to use a mask 
(mask with filtration). 

 

7.2 Changing collector bag 

Always disconnect the dust collector 
from the power source (unplug) before 
servicing or changing filter. 

During the changing or cleaning of the 
collector bag it’s necessary to use a 
mask (mask with filtration). 

 

8. Trouble shooting 

Unit 

doesn’t start 

*No electricity- 
                          check mains and fuse. 

*Defective switch, motor or cord- 
                           consult an electrician. 

 Air flow too weak 
 

*

Clogged filter- 

                                           Clean filter. 

9. Environmental protection 

Protect the environment. 

Your appliance contains valuable 
materials which can be recovered or 
recycled. Please leave it at a 
specialized institution. 

 

This symbol indicates separate 
collection for electrical and electronic 
equipment required under the WEEE 
Directive (Directive 2012/19/EC) and is 
effective only within the European 
Union. 

 

10. Available accessories 

Stock number 10000315 

PVC-hose transparent, Ø100mm, 
length 2,5m

 

Stock number JW1022

 

Hose clamp Ø100mm 

Further dust collection accessories 
available, see JET price list. 

Summary of Contents for DC-1200

Page 1: ... DC 1200CK M DC 1200CK T Dust Collector Dust Collector with Canister Original GB Operating Instructions TOOL FRANCE SARL 9 Rue des Pyrénées 91090 LISSES France www jettools com 10001057M T 10000078M T 2019 03 ...

Page 2: ...2014 30 EU electromagnetic compatibility elektromagnetische Verträglichkeit compatibilité électromagnétique 2011 65 EU RoHS directive RoHS Richtlinie Directive RoHS designed in consideration of the standards und entsprechend folgender zusätzlicher Normen entwickelt wurde et été développé dans le respect des normes complémentaires suivantes EN 60335 1 2012 A11 2014 EN 60335 2 69 2012 EN 62233 2008 ...

Page 3: ...rer Materials such as liquids metal shavings metal dust screws glass plastic or rock can cause sparks and or damage when coming into contact with any part of the dust collector The product is not suitable for use in wet or humid environment Don t use appliance in places with a risk of explosion The proper use also includes compliance with the operating and maintenance instructions given in this ma...

Page 4: ...0mm Net weight 38 kg Overall DC 1200CK M T LxWxH 1000x750x1900mm Net weight 47 kg Mains 230V 1 N PE 50Hz Input power 1 5kW 2HP S1 Reference current 7 3 A Extension cord H07RN F 3x1 5mm Installation fuse protection 16A Mains 400V 3L PE 50Hz Motor input power 1 5kW 2HP S1 Reference current 2 8 A Extension cord H07RN F 4x1 5mm Installation fuse protection 10A Isolation class B 4 2 Noise emission Acou...

Page 5: ...ig 7 Install the housing A Fig 8 with 6 hex cap screws Fig 8 Hose Attach the hose A Fig 9 with 2 provided clamps B Fig 9 Install the filter bag DC 1200 Attach the loop of the filter bag to the filter bag hanger M Place the filter bag A over the bag support housing Place a bag clamp B over the bag and close the clamp Fig 10 Note make sure the bag is fastened securely so that no dust will escape dur...

Page 6: ...nance work on the electrical system may only be carried out by a qualified electrician 7 1 Cleaning Filters Shake the filter bag whenever it is clogged and before each collector bag change When the air flow reduces the filter must be cleaned To clean the filter on DC 1200CK M T turn the handle I Fig 10A a couple of rotations so the dust falls into the collector bag ATTENTION During the changing or...