![Jesco FEDOS DX 17 Operating Manual Download Page 7](http://html1.mh-extra.com/html/jesco/fedos-dx-17/fedos-dx-17_operating-manual_644925007.webp)
2. General
2.1 Proper intended use
The device is intended for the following purpose only: the conveying and dosing of chemicals.
Operating safety is guaranteed only if the device is used for its intended purpose. All other types of use are
prohibited and will invalidate the warranty. The operating conditions described in chapter 5 "Technical Data"
must be observed!
2.2 Structure of the dosing pump
c
a
h
b
i
o
p
q
g
k
n
m
l
f
e
j
a
Dosing head
b
Suction side valve
c
Discharge side valve
e
Stroke length adjustment
f
Stroke length adjustment lock
g
Motor terminal box (FEDOS E voltage supply)
h
Oil inlet
i
Oil outlet
j
Control unit (FEDOS DX)
k
Operating panel with display
l
"External switch-off" contact
m
"Level input" contact
n
"External control" contact
o
Voltage supply (FEDOS DX)
p
Motor connection
q
Fault signalling relay
General | Operating Manual FEDOS E/DX |
7