JEONGWOOD TSA-500 Instruction Manual Download Page 1

 

░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░ 

INSTRUCTION MANUAL 

░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░░ 

 

AC TYPE SPOT WELDING MACHINE 

Model : TSA-500 

 

AC TYPE WELDER CONTROL SYSTEM TSA-500 

AC TYPE WELDER TRANSFORMER TST-5T(10T) 

 
 
 

 

 

 

Battery Specialist

 

-------------------------------------------

 

                               

JEONGWOOD TRADING CORP

Room 1509, Seongsoo Academy Tower, 277-17 Seongsoo-Dong 2-Ka,   

Seongdong-Ku, Seoul, Korea. 

                                                Tel : 82-2-3436-1212        Fax : 82-2-3436-1279 

E-mail : 

[email protected]

       

[email protected]

URL : 

http://www.jeongwood.co.kr

 

PLEASE READ THIS MANUAL BEFORE OPERATION OF WELDING MACHINE. 

 

Summary of Contents for TSA-500

Page 1: ...RANSFORMER TST 5T 10T Battery Specialist JEONGWOOD TRADING CORP Room 1509 Seongsoo Academy Tower 277 17 Seongsoo Dong 2 Ka Seongdong Ku Seoul Korea Tel 82 2 3436 1212 Fax 82 2 3436 1279 E mail jeonguj empal com uj jeongwood co kr URL http www jeongwood co kr PLEASE READ THIS MANUAL BEFORE OPERATION OF WELDING MACHINE ...

Page 2: ... transformer 2 Model Welding controller TSA 500 Welding transformer TST 5T 3 Input voltage AC 220V 380V 10 20 4 Frequency 50 60Hz 5 Control method Thyristor controlled by 1 chip micro computer 6 Number of timer setting 10 kinds of setting Squeeze Pressure time Up slope Current increase Heat 1 Weld 1 Cool 1 Heat 2 Weld 2 Cool 2 Heat 3 Weld 3 Down slope Current decrease Hold Off time 7 Timer setting...

Page 3: ...erate and standby of operation Four digits count are displayed in this mode f PGM Key Program mode Two digits setting value are displayed in this mode g W ON Key Weld On Key h W OFF Key Weld Off Key i SIN Key This key is to take only one time operation from Squeeze time to Hold time by one time continuous input and then stop the operation j REP Key This key is to take repeat operation from Squeeze...

Page 4: ... figure into 0 8 When HEAT3 lamp is on by push key use and key to set figure into 0 9 When DNSL lamp is on by push key use and key to set figure into 0 10 When HOLD lamp is on by push key use and key to set figure into 0 11 When OFF lamp is on by push key use and key to set figure into 0 12 When HEAT1 and lamp are on by push key use and key to set figure into 40 13 When HEAT2 lamp is on by push ke...

Page 5: ...em 17 repeatedly and increase figure setting 19 When you push PGM key and lamps are on at HEAT1 you may use and key to set figure into 2 or 3 instead of 1 Ref To item 4 However nickel tags may be oxidized into dark if you set at 3 or higher figure So you are requested to set it 1 or 2 Before shipment we did weld test and welding condition is properly set for your immediate use If this setting is a...

Page 6: ...4 Front Panel of Power Supply 6 ...

Page 7: ...5 Circuit Block Diagram of Back Panel 7 ...

Page 8: ... 8 ...

Page 9: ...TSA 500 Spot Welding Machine Pictures 9 ...

Page 10: ...Wiring View of TSA 500 Spot Welding Machine 10 ...

Page 11: ...TSA 500 Spot Welding Machine Wiring Diagram 11 ...

Page 12: ...sformer Changing 40 into 45 weld output is increasing too In case 40 is an ideal weld condition 45 or 50 will result excess of weld output and it may cause weld splash excess melt and weld electrode may be easily worn out CYCLE means time to flow output current 1 cycle 16ms Higher cycle means more time to flow weld current 3 Once started it is available to get three output HEAT1 HEAT2 and HEAT3 Wh...

Page 13: ...r line is showing by and CYCLE lower line Time to flow current is showing by COOL1 Cooling time between HEAT1 and HEAT2 HEAT2 Heating energy to melt material 2nd Current upper line is showing by and CYCLE lower line Time to flow current is showing by COOL2 Cooling time between HEAT2 and HEAT3 HEAT3 Heating energy to melt material 3rd Current upper line is showing by and CYCLE lower line Time to fl...