background image

                    PowerPlus Amplifiers

11

Indicators and Controls

Power Indicator (POWER)

The power indicator provides a visual indication that the amplifier is turned on.

Input Level Control (LEVEL/GAIN)

The INPUT LEVEL control (or GAIN) matches the output of your radio to the 
input of the amplifier. After the installation is complete, make sure the input 
level control on the amplifier is turned down all the way (counter-clockwise or 
all the way to the left). Play a tape or CD (make sure bass and treble settings 
or Bass EQ are flat) and turn the volume up slowly until you just start to hear 
distortion. Back the volume down just a bit. On the amplifier, slowly turn up the 
input level control (clockwise or to the right) until you just start to hear 
distortion, then back it down a bit. Now your radio and amplifier levels are 
matched.

BASS EQ

The Bass EQ is continuously adjustable from 0 to +12dB @ 45Hz. Adjusting 
the Bass Boost level allows different subwoofer/enclosure combinations to be 
equalized. Use this control to increase the level of low bass available from your 
subwoofer/enclosure combination. Ported and Band Pass enclosures should 
be limited to about +6dB to +9dB of boost. Sealed enclosures should be able 
to accept the full +12dB of boost, if necessary. The full +12dB of boost should 
be reserved for special applications since improper use of the Bass Boost 
could damage your subwoofers at high volumes.

Low Pass Filter (LPF)

The Low Pass Filter controls adjust the crossover point. Typical crossover is 
between 60Hz and 80Hz for ported and sealed enclosures. Bandpass boxes 
will typically use a higher crossover setting between 125Hz and 150Hz. Since 
musical tastes vary, you should play music that you would normally listen to in 
your vehicle, with the above settings as a starting point. If necessary, set the 
crossover by ear.

High Pass Filter (HPF)

The high pass filter will limit the low frequencies being transmitted to your 
speakers. This can be useful in number of situations. For example, if you 
selected the high pass filter and set the crossover to 40Hz, then you would 
have an infra-sonic (sub-sonic) filter at 40Hz, which would be useful with 
certain enclosure/subwoofer combinations that were tuned between 45Hz and 
50Hz. Other uses might include limiting the low frequencies to smaller 

speakers (6 1/2", 6 X 9", etc.) by adjusting the crossover to a higher setting 
(80–100Hz).

Crossover (X-OVER)

The Jensen PowerPlus series of amplifiers have built-in low-pass and high-
pass crossover filters for bi-amplifying the system. Adjust the crossover to 
accommodate your chosen installation method. Select LPF (low pass filter) 
when the amplifier will be driving woofers or subwoofers. Choose FULL or OFF 
when crossover mode is not active and the amplifier is in “full range” mode. 
Select HPF (high pass filter) when the amplifier will be driving full-range or 
separate speakers, and you want to limit the “bass” being transferred to these 
speakers.

Mode Switch

PowerPlus 420 and 1302

The 420 and 1302 come equiped with a ST/MO (stereo/mono) MODE switch. 
Use STEREO mode when you have a 2-channel input from the source unit. 
Use MONO mode when you have a single input from the source unit. See 
“Input Wiring” on page 9.

PowerPlus 840 and 1304

The 840 and 1304 come equiped with a 4/3/2 MODE switch and can be 
configured for three different input modes: 2 channel, 3 channel or 4 channel.

Summary of Contents for PowerPlus 900

Page 1: ...ion Manual Contents Introduction 2 Features and Specifications 3 Installation 4 Wiring 5 Speaker Wiring 7 Indicators and Controls 11 Testing 12 Remote Input Level Control 12 Troubleshooting 13 CEA Pow...

Page 2: ...So feel confident that your Jensen purchase decision was a sound one and remember If it s Too Loud You re Too Old Before You Begin We need to get the legal stuff out of the way so please keep reading...

Page 3: ...ode switch PowerPlus 840 and 1304 PowerPlus 1302 Low Pass filter 50 250Hz High Pass filter 40 500Hz High Pass Low Pass Full Range selector switch Stereo Mono Mode switch Remote Input Level Control w 5...

Page 4: ...t the negative battery cable before starting the installation Check the battery ground there should be two 2 ground wires coming from the battery one going to the starter mounting bolt or engine block...

Page 5: ...eries can be installed if desired Use the following recommended wire gauge as a guide when installing your amplifier s Power Terminal 12V B Connect the main power wire to the battery within 18 inches...

Page 6: ...are metal Use a ring terminal of the proper gauge and an outside star washer between the chassis and ring terminal when making your ground connection Although you ve scraped away the paint to expose b...

Page 7: ...For maximum power configure your speakers for a nominal 2 ohm load NOTE Do not overlook the use of the proper gauge speaker wire The PowerPlus series of amplifiers require a minimum of 12 gauge wire...

Page 8: ...LPF OFF SPEAKER OUTPUT BRIDGED BRIDGED CH1 CH2 CH3 CH4 4 ohm nominal 2 ohm minimum 4 ohm nominal 2 ohm minimum HPF LPF OFF HPF LPF OFF SPEAKER OUTPUT BRIDGED BRIDGED CH1 CH2 CH3 CH4 4 ohm nominal 4 oh...

Page 9: ...annel or 4 channel RCA Cable CAR STEREO SOURCE UNIT RCA Cable CAR STEREO SOURCE UNIT Input Wiring Mono Mode Input Wiring Stereo Mode MODE 4 3 2 2 Channel 40Hz 240Hz 40Hz 400Hz 0dB 12dB 5V 0 4V X OVER...

Page 10: ...Connecting Additional Amplifiers Pass Thru RCA connectors are provided to connect additional amplifiers without the need to purchase Y adapters MODE 4 3 2 HPF LPF OFF 5V 0 4V 0dB 12dB 40Hz 400Hz 40Hz...

Page 11: ...ly use a higher crossover setting between 125Hz and 150Hz Since musical tastes vary you should play music that you would normally listen to in your vehicle with the above settings as a starting point...

Page 12: ...both speaker wires may be disconnected Remote Input Level Control The PowerPlus 900 1150 and 1302 come equipped with a Remote Input Level Control The Remote Input Level Control allows the input level...

Page 13: ...lternator whine Ground loop s Use good quality shielded RCA cables Faulty ground at amp Re ground amp to clean bare metal chassis Faulty ground at head unit Re ground head unit to clean bare metal cha...

Page 14: ...uency Response 10Hz to 240Hz 3dB Reference 1 watt Dimensions L17 25 x H2 5 x W11 75 PowerPlus 1150 Power Output 330 watts RMS X 1 channels into 4 ohms 1 THD N Signal to Noise Ratio 100dBA below refere...