24
For direct-wired ranges:
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.
Disconnect power.
2.
Slide range forward.
3.
Turn manual shutoff valve to the closed position.
4.
Disconnect the gas supply tubing.
5.
Complete cleaning or maintenance.
6.
Reconnect the gas supply tubing.
7.
Open the manual shutoff valve in the gas supply line.
8.
Test for leaks using method described in "Make Gas
Connection" section.
9.
Check that the anti-tip bracket is installed and engaged. See
the "Verify Anti-Tip Bracket Is Installed and Engaged" section.
10.
Check that range is level.
11.
Reconnect power.