background image

Summary of Contents for RADIANT COOKTOP CVE3401

Page 1: ...r a side clearanceof at least 6 15 24 cm is recommendedfor optimumventilation NOTICE TO INSTALLER Leave these instructionswith the appliance NOTICE TO CONSUMER Retain these instructions for future reference 29 3 4 _ 75 27 cm _ _ _ 22 _ 28 7 8 _1 16 _ 21 1 8 1 8 73 05cn_ 16 cm 53 66cm 52 cm tO CUT I _ I SELECT APPROPRIATE I _ _ DUCT CUTOUT L BLOWERMAY BE ROTATED _ _ FOR t K_IZONTAL OR _ _ n VERTICA...

Page 2: ... 5 inches beyond the bottom of the cabinets in accordance with local codes and properly insulated Check with local utilityfor governing electrical codes and ordinances In the absence of local electrical codes the iF National Electrical Code NFPA No 70 governing electric DOTTED LINES range installations must be followed A copy of the INDICATE RANGE HOOD U National Electrical Code NFPA No 70 can be ...

Page 3: ...to desired position Connect outlet blower CAUTION housing to vent duct Tighten cap nuts inside plenum Neveruse a metal bladeto pry knob off If knob 5 Remove attachment screw and cover from junction cannot be easily removed tuck folds of a box Connect BXcable toknockout onsideof the junction box Make wire connections push wires into dishtowelunder knob skirt and pullupwardwith junctfon box Re attac...

Page 4: ...ts are necessary observe the following B 30 76 2 cm minimum clearance between the top oftbe cooking platform and the bottom of an unprotected wood or metal cabinet B 24 60 96 era minimum when bottom of wood or metal cabinet is protected by not less than 1 4 0 635 era FLAME RETARDANT millboard covered with not less than No 28 MSG sheet steel 0 015 0 038 era stainless st_l 0 024 0 061 cm aluminum or...

Page 5: ... on line to clear floor joist Recheck your dimensions and make the cutout ONTHIS UNE k I _ 12 WALL VENT CUTOUT Locate the vertical studs in the rear wall Studs are us_liy 16 40 64 cm center to center Will the vent duct be 6 15 24 cm round through the wall or 3 1 4 x 10 8 26 cmx 25 4 cm rectangle vertically iuside the wall See Ducting Instructions for rear duct inside the wall NOTE Cutout in wall m...

Page 6: ... blower Direct Connect Pull through 5 152 4 era of electrical cable Use three or four conductor copper stranded power cable see front cover for proper wire size If four conductor wire is used see 16 for connection to range See front cover for proper supply connection j 1 4 ho 11 43_ J t 5 FE_ TOF ELECTRICAL CABLE 15 COI_E CT ELECTRICAL THREE CONDUCTOR W1KE CAUTION Make sure power to cable is OFF R...

Page 7: ...through the cable clamp Make a loop in the bare ground wire and attach it to the range with the sCrew that held the ground strap Attach the BLACK RED and WHITE wires see 15 Tighten the terminal block nuts and the cable clamp Tape the ground stra to the WHITE wire as shown InstaLlelectrical cover up II I I 17 INSTALL OPTIONS If a backsplash or side panels are to be used install according to instruc...

Page 8: ...brackets forward 1 8 318 era If a non lighted backsplash is used move back of brackets forward 1 4 635 eta NOTE Leg levelers mustbe screwed out I 1 2 turns If the flOorwill not accept the wood screws supplied alternate fasteners taust be supplied by the installer _TERNA_ SCREW HOLE tFw_0 t_ 27 t 70 80 erni 1 58 cm 20 LEVEL RANGE Free Standing Adjustthe leveler feet to level range with the countert...

Page 9: ...er side 8e sure to remove all packaging materials from unit prior to applying power Switch the electrical circuit breaker to the ON position Consult Owner s Manual for operation Check range top elements Fan comes on automatically when grill is turned on cooking cartridge does not energize fan automatically Check oven Check vent fan With vent fan on check all vent duct connections to the outside to...

Reviews: