7
The power cord of this appliance is equipped with a 3-prong
(grounding) plug which must be used with a properly grounded
3-hole outlet with a standard 120 V, 60 cycle AC household
current. If you do not have a 3-hole grounded outlet, have a
qualified electrician change your old one. A grounding adaptor will
be needed to convert the old one until the outlet can be replaced.
This method is only temporary, and a qualified electrician should
test it to be sure it meets requirements.
Electrical Requirements
Do not under any circumstances cut or remove grounding
prong from the cooktop cord.
N
L
A
A.
Grounding prong
Gas Supply Requirements
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14
ʺ
(36 cm) water
column.
Examples of a qualified person include: licensed heating
personnel, authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A QUALIFIED SERVICE MAN OR GAS APPLIANCE
INSTALLER MUST MAKE THE GAS SUPPLY CONNECTION.
Observe all governing codes and ordinances.
IMPORTANT:
This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with the National Fuel Gas Codes ANSI Z223.1/NFPA 54
or, in Canada, the Natural Gas and Propane Installation Code,
CSA B149.1 - latest edition.
Leak testing of the appliance shall be conducted by the installer
according to the instructions given. You must install the supplied
connection parts seen here in this configuration to the main gas
manifold on the appliance. Issues arising from a failure to do so
will not be covered by warranty.
Do not install the pressure regulator backwards as the gas will not
flow correctly. Check that the arrow on the back points in the
direction of gas flow.
Parts required for connection from gas supply to regulator are the
responsibility of the installer/owner.
A
B
C
D
A.
Appliance pressure regulator
B.
Flare union adaptor
C.
Gasket
D.
Appliance
NOTE:
Use
TEFLON
®
✝
tape
rated
for
gas
applications
at
all
threaded
connections.
Do
not
overtighten
the
connection
at
the
manifold
or
you
could
damage
the
gasket
causing
a
leak.
IMPORTANT:
If
the
line
pressure
supplying
the
appliance
pressure
regulator
exceeds
14
inches
W.C.
(any
gas),
an
external
regulator
must
be
installed
in
the
gas
line
ahead
of
the
appliance
regulator
to
reduce
the
pressure
to
prevent
malfunction
and
damage
to
the
appliance.
Important
Notes
for
Gas
Connection
The
appliance
and
its
individual
gas
shutoff
valve
must
be
disconnected
from
the
gas
supply
piping
system
during
any
pressure
testing
of
that
system
at
test
pressures
in
excess
of
1/2
psi
(3.5
kPa).
The
appliance
must
be
isolated
from
the
gas
supply
piping
system
by
closing
its
individual
manual
shut-off
valve
during
any
pressure
testing
of
the
gas
supply
piping
system
at
test
pressures
equal
to
or
less
than
1/2
psi
(3.5
kPa).
All
supply
piping,
except
as
noted,
should
use
common
National
Pipe
Thread
(NPT).
For
all
pipe
connections
use
an
approved
pipe
joint
compound
resistant
to
the
action
of
propane
gas.
This
appliance
is
designed
for
use
with
natural
gas
or
propane
gas.
The
gas
pressure
regulator
is
supplied
with
this
appliance.
It
must
be
installed
in
the
gas
way
ahead
of
the
manifold
entrance.
It
is
pre-set
for
use
with
natural
gas.
To
use
it
with
different
gas
it
must
be
converted,
as
described
in
the
Gas
conversion
paragraph.
If
at
any
time
the
appliance
is
to
be
used
with
a
different
type
of
gas,
all
the
conversion
adjustments
must
be
made
by
a
qualified
technician
before
attempting
to
operate
the
cooktop
on
that
gas.
The
gas
should
be
supplied
to
the
appliances
pressure
regulator,
at
line
pressure
between
6"
(15.24
cm)
and
14"
(35.56
cm)
of
water
column
for
natural
gas,
and
between
11"
(27.94
cm)
and
14"
(35.56
cm)
of
water
column
for
propane
gas.
GAS REQUIREMENTS
NATURAL GAS
WC
Manifold Pressure
5" (12.5 mb)
Minimum Line Pressure
6" (15 mb)
Maximum Line Pressure
14" (34.9 mb), .5 psi (3.5 kPa)
✝
TEFLON
®
is a registered trademark of Chemours.
Summary of Contents for JGCK424PS
Page 31: ...NOTES...