background image

6

4. Drill two 

¹⁄₈

" (3 mm) holes that correspond to the bracket 

holes of the determined mounting method. See below.

Floor Mounting 

Wall Mounting

5. Using the Phillips screwdriver, mount anti-tip bracket to the 

wall or floor with the two #12 x 1

⁵⁄₈

" screws provided.

Electrical Connection

Power Supply Cord

Direct Wire

1. Disconnect power.

2. Use Phillips screwdriver to remove the terminal block cover 

screw located on the back of the range. Pull cover down and 
toward you to remove cover.

3. Remove plastic tag holding three 10-32 hex nuts from the 

middle post of the terminal block.

A. #12 x 1

⁵⁄₈

" screws

B. Anti-tip bracket

A

B

A. #12 x 1

⁵⁄₈

" screws

B. Anti-tip bracket

A

B

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

Summary of Contents for JER8895BAS - 30" Electric Double Oven Range

Page 1: ...injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury a...

Page 2: ...that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip b...

Page 3: ...retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooki...

Page 4: ...r circuit breaker box through flexible or nonmetallic sheathed copper or aluminum cable See Electrical Connection Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved...

Page 5: ...maximum of 1 2 5 cm A minimum of 5 mm is needed to engage the anti tip bracket NOTE If height adjustment is made when range is standing tilt the range back to adjust the front legs then tilt forward...

Page 6: ...n and toward you to remove cover 3 Remove plastic tag holding three 10 32 hex nuts from the middle post of the terminal block A 12 x 1 screws B Anti tip bracket A B A 12 x 1 screws B Anti tip bracket...

Page 7: ...nduit plate down and out Position cord conduit plate as shown in the following illustration Replace cord conduit plate and insert screws Assemble a UL listed conduit connector in the opening Feed the...

Page 8: ...rminal block posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use wit...

Page 9: ...nnected directly to the fuse disconnect or circuit breaker box Depending on your electrical supply make the required 3 wire or 4 wire connection 1 Strip outer covering back 3 7 6 cm to expose wires St...

Page 10: ...s 7 Connect line 1 black and line 2 red wires to the outer terminal block posts with 10 32 hex nuts 8 Securely tighten hex nuts 9 Replace terminal block access cover 3 wire connection Direct Wire Use...

Page 11: ...for satisfactory baking conditions CompleteInstallation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have...

Page 12: ...nge forward 3 Complete cleaning or maintenance 4 Check that anti tip bracket is installed Look for the anti tip bracket securely attached to floor or wall Slide range back so rear range foot is under...

Reviews: