20" (50.8 CM), 30" (76.2 CM) AND 43" (109.2 CM)
ELECTRIC DOWNDRAFT COOKTOP
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10421939B
8/7/12
PRODUCT MODEL NUMBERS
CVEX4100
CVEX4270
CVEX4370
PRODUCT DIMENSIONS
ELECTRICAL REQUIREMENTS:
Before You Make the Electrical Connection:
●
A 4-wire or 3-wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply is
required on a separate, 40-amp circuit (30" [76.2 cm] models), 20-amp circuit
(20" [50.8 cm] models) or 60-amp circuit (45" [114.3 cm] models), fused on both
sides of the line.
A. Side clearance - See *NOTE.
B. 4¾" (12.0 cm)
C. 6¼" (15.9 cm)
D. Grease container
E. 2" (5.0 cm) min. to cabinet,
6" (15.2 cm) recommended to motor service
F. 12½" (31.8 cm)
G. 17½" (44.5 cm)
B
C*
G
A
D
E**
F
20" (50.8 cm) Single Cartridge Cooktop
A. 19¼" (48.9 cm)
B. 21
¹⁄₈
" (53.6 cm)
C. Grease container
D. Blower
A
B
C
D
*
NOTE:
Grills installed near a side wall must allow a minimum clearance of 6"
(15.2 cm) between cooktop and sidewall for maximum performance. Minimum
clearance of 1" (2.5 cm) is required to sidewalls and
³⁄₄
" (1.9 cm) to rear wall.
*
*A minimum clearance of 6
¹⁄₄
" (15.9 cm) is recommended for removal of the
grease filter(s). Installed dimension for the grease filter(s) is 5
¹⁄₂
" (14.0 cm).
**A minimum clearance of 2" (5.1 cm) is required between the blower motor and
cabinet for proper cooling. A clearance of 6" (15.2 cm) is recommended to allow
for blower motor service.
B
C*
E**
F
A
H
D
D
G
30" (76.2 cm) Double Cartridge Cooktop
A. 30
¹⁵⁄₁₆
" (78.6 cm)
B. 21
¹⁄₈
" (53.6 cm)
C. Grease container
D. Blower
A. Side clearance - See *NOTE.
B. 4¾" (12.0 cm)
C. 6¼" (15.9 cm)
D. Grease containers
E. 2" (5.0 cm) min. to cabinet,
6" (15.2 cm) recommended to motor service
F. 12½" (31.8 cm)
G. 11
⁷⁄₁₆
" (29.1 cm)
H. 17½" (44.5 cm)
A
B
C
D
*
NOTE:
Grills installed near a side wall must allow a minimum clearance of 6"
(15.2 cm) between cooktop and sidewall for maximum performance. Minimum
clearance of 1" (2.5 cm) is required to sidewalls and
³⁄₄
" (1.9 cm) to rear wall.
*
*A minimum clearance of 6
¹⁄₄
" (15.9 cm) is recommended for removal of the grease
filter(s). Installed dimension for the grease filter(s) is 5
¹⁄₂
" (14.0 cm).
**A minimum clearance of 2" (5.1 cm) is required between the blower motor and cabinet
for proper cooling. A clearance of 6" (15.2 cm) is recommended to allow for blower
motor service.
43" (109.2 cm) Triple Cartridge Cooktop
A. 42
¹⁹⁄₃₂
" (108.2
cm)
B. 21
¹⁄₈
" (53.6 cm)
C. Grease container
D. Blower
A
B
C
D
¹⁹⁄₃₂
Page 1 of 2