Jeio tech IB-05G Operation Manual Download Page 1

 
 
 
 

 
 

Page   

1

 

   

Operation manual 

[INCUBATOR] 

Model : IB-05G / 15G / 25G

 

Manual No : 00HAA0001141 ( Version : 5.0 ) 

 

 

 

 

 

This operation manual describes the important subjects to maintain 

the product’s functions and to use it safely. Especially, be sure to 

read <Safety Precaution> carefully before you use this equipment. 

Please  keep  this  manual  close  to  the  equipment  to  use  it  after 

reading through it once. Please place it where the new user can 

find  it  easily  for  the  safety  use  when  you  hand  over  or  lend  the 

equipment to others.

 

 

 

Summary of Contents for IB-05G

Page 1: ...maintain the product s functions and to use it safely Especially be sure to read Safety Precaution carefully before you use this equipment Please keep this manual close to the equipment to use it after reading through it once Please place it where the new user can find it easily for the safety use when you hand over or lend the equipment to others ...

Page 2: ...a big accident in case of improper use of inflammable and combustible solvents in the chamber Also operation in the high temperature might cause a mechanical trouble and quality deterioration due to the function and the characteristic of the product Safety Precautions Danger means that the user may have serious damage and even die by improper handling on this unit Warning means that the user may h...

Page 3: ...tions in this manual Please be sure to pay attention to the directions and be cautious so that a mechanical trouble or an accident would not be occurred 2 Warning mark of product The most important thing of the warning is a warning label attached to the product It is located in front of the door Be fully aware of the warning contents during operation Please change to the new warning label when it ...

Page 4: ... Installation 6 3 Notice 7 4 Name of the parts 8 5 Operating Controller 11 6 Maintenance 18 7 Dealing with Abnormal Condition 19 8 Guarantee 20 9 Equipment Disuse 20 10 Specifications 21 11 Install lab tracer 22 12 How to use lab tracer 23 ...

Page 5: ...safety device specialized for individual model Laboratory must have Thermal safety secure because there are a lot of inflammable reagent This system is highest safety secure control device patent No 0397583 0328729 and makes the unit suitable for this kind of environment 3 This unit is designed to stop the Heater and Blower in order to protect the user from heat when its door opened while it works...

Page 6: ...et the unit located in ambient temperature range in 5 C 40 C relative humidity lower than 80 5 Please don t install the unit where water and organic solvent is easily penetrates in the unit They cause short circuit 6 Please don t install the unit in dangerous place Where there are flammable gas and explosive material 7 Please secure enough space for installation because the door of it opened 180 8...

Page 7: ...e materials near by oven 5 Please don t pour water on the unit directly when you clean the unit 6 Please don t put some conductive and flammable materials through ventilation or power supply port It is dangerous and causing fire and electric shock 7 Circuit and electric component used in this unit are developed by Jeio tech Please don t try to repair by yourself Wrong combination of electric part ...

Page 8: ...rning and electric shock 3 Shelf level adjustor Shelf level is easily adjustable by the size of sample IB 05G 8 levels IB 15G 12 levels IB 25G 14 levels 4 Shelf It s made by Stainless steel wire It s easy to clean and ventilation is good The surface of it is electrically polished therefore it has beautiful face good anti corrosion 5 Door There are air barrier between door surface and insulation of...

Page 9: ...f the chamber 10 Temperature Controller This has a Micro processor CPU which has Digital PID Auto tuning function It also has temperature compensation function for temperature sensor and the highest class safety level control system such as heating volume controller 11 Over temp Limit If the heater temperature rises higher than set temperature it cut the power of the temperature controller makes t...

Page 10: ...d com2 port through RS 232C protocol cable 16 Foot This adjusts level of the instrument 17 Inner Door limit switch It s installed inside of the unit The Logic IC of this switch put off the main switch This cut off all 2 phase currency in the instrument therefore heater and blower stops for safety of user Door LED blinking to indicate the door is opened If the door is opened more than 1 minute then...

Page 11: ...y by audio and visual device then keeps in safe mode until all instability conditions removed 3 CLS Control System gives user two choice one is resume operation of the unit and another is keeps the unit in standstill when the unit operation were terminated by power failure and then recovered 4 CLS Control System the safety device designed to keep very small amount of currency only 5V 10mA in conta...

Page 12: ...gher than set temperature it cut the power of the temperature controller makes the over temperature LED blinking and alarming beep sounds If you resume the operation please set knob of it about 15 higher than set temperature and press Start Stop switch ones then check run led of temperature 7 Temp button This button is for temperature setting 8 Timer button This button is for timer setting 9 Up bu...

Page 13: ...ature and showing remaining time when the timer function is activated 17 PV display This display is for showing present temperature 3 Temperature setting way 1 Press button Set temperature value SV is blinking This means you can vary set value 2 Press button to vary digit number and press button when you save the value 3 It goes back to previous state without saving if you don t touch any button f...

Page 14: ... Sv2 Sv3 are shown and temperature unit set mode shown by pressing 5 times repeatedly 2 This is a function vary the unit of temperature value Initial display is and it can be varied and by pressing and buttons 3 Next mode is shown by pressing 6 times This compensates the temp value errors Requested values are put on PV display Move to the next mode by pressing and 00000buttons PV is put on the SV ...

Page 15: ...g button and Save by pressing button 2 W ON LED turns on with Beep sound after finishing wait on timer set 3 Press button two times You can set wait off timer Set time by pressing button and save and finish by pressing button 4 W OFF LED turns on with Beep sound after finishing wait on timer set 5 The function of Timer is as follows ...

Page 16: ...n of Wait On Timer Wait Off Timer The unit works as picture above 6 Set off Wait on off Timer Press button one Wait on Timer or two Wait off Timer times and set Z 0 by pressing and finally press to set off 6 Additional function of button The following Auto Run function is shown by pressing button thee times repeatedly 1 This is for compensating function after power failure If you set yes the unit ...

Page 17: ...uto Tune is working with flickering A T LED 5 Auto Tune time is various according to installed environment LED turns off after finishing Auto Tune and Present temperature Set temperature meet 8 Key Lock This is to lock controller buttons 1 Press button for a while 3seconds then Lock function is set with Beep sound and the unit wouldn t corresponding any more key pressing 2 In order to deactivate t...

Page 18: ...ft cloth containing distilled water 5 Dry with dry cloth 6 Don t use organic solvent 7 If user try to clean this unit with other method not mentioned on this manual please contact us in order not to damage to the unit 8 Put on Safety glove for harmful chemicals and Safety Mask for harmful gas and then wash out pollutant with dried cloth when harmful chemicals and gases are spread out on the unit ...

Page 19: ...in the chamber Check the door switch open and close the door 2 3times Check the blower works correctly Abnormal sound Check the Impeller of blower is OK inside of the chamber Open the back plate of the instrument and Check the Impeller of Blower touches any part No power Check the Main power Switch is on Check the power supply is on in the room Check the power failure Check the fuse is OK Temperat...

Page 20: ... service wrong operation by users Wrong usage and management Wrong remodeling and repair by users Break down by natural calamity Different usage from operation manual 9 Equipment Disuse keeps an abolition way if disposes of a product or parts and please dispose of abolition An abolition way of main configuration parts Configuration Parts Model Weight Kg Size mm An abolition way Main Body IB 05G 45...

Reviews: