T464 Installation and Setup
20090709 v1r0 JED Microprocessors Pty. Ltd. - Page 16 of 27
Load Semi-static Data from T460
If new equipment is installed in a room, or old audio and visual devices are
changed, the T460 must be reconfigured. This usually involves changing the
names of the available channels, etc. Most information displayed at the
administration terminal will not change unless the T460 is reconfigured. This is
the ‘Semi-static Data’.
T460 Flags
The T460 FLAG ‘E’ must be set to enable communication with the T464.
Please consult the latest
for instructions on how to
set FLAG ‘E’. Please ensure that the
is the latest version.
When the T464 is powered up and finds a connected T460, some T460
configuration information is checked. If the T464 copy of the T460 information
is different due to reconfiguration, it will refresh that information about 45
seconds after power is applied.
The current copy of T460 information stored in the T464 may be displayed by
selecting the Setup Menu option ‘v’.
The following panel illustrates output after selecting option ‘v’:
Enter Function - [h(elp) - a|i|j|k|l|v|ESC]: v
Current vales for offline use:
CH1 : SKIP CH1
CH2 : SKIP CH2
CH3 : SKIP CH3
CH4 : SKIP CH4
CH5 : SKIP CH5
CH6 : SKIP CH6
CH7 : SKIP CH7
CH8 : SKIP CH8
ser0 : 038400,8,N,1
ser1 : 038400,8,N,1
make : *MAKE HERE*
sw ver : T460Vxxxx
model : *MODEL HERE*
filter : 00000
lamp : 00000
audio type : 0
connected device type: 0
volume type : 0
Update? y/n:
Example of values in a new T464, before T460 options are loaded