background image

32

Accessories

TP310

 - #1 to 10 F-Connector Mapping 

Remote

TP311

 - #1 to 20 F-Connector Mapping 

Remote

TP312

 - #1 to 20 RJ45 Plug Mapping 

Remote

TP314

 - #1 to 20 RJ11 Plug Mapping 

Remote

TP608

 - Set of 7 numbered Full remotes

TP20

 - 7�5” cable assembly with no-fault 

6 position plugs, reverse-pinned�  Use 

to map and test 2, 4 or 6 pin telephone 

wiring�  Can be used with RJ45 (8-

position) jacks and will not damage 

them�

TP56

 - Patch Cable Assembly, RJ45, 

without shield

TP40

 - Cable Assembly, RJ45 / Alligator 

12” LAN

Summary of Contents for TestifierPRO

Page 1: ...TestifierPROf Test Set User s Guide www jdsu com hbn a2007 JDSU All rights reserved...

Page 2: ......

Page 3: ...Power Button Setup Up Button Telco Mode Button Coax Mode Button LCD Screen Network Mode Button Down Button Select Button Remote Data Jack Telephone Jack Telephone Jack Data Jack F Connector Jack Coax...

Page 4: ...for Use 17 Cable Testing 17 To Map Cable ID s 20 To Place Tone on a Cable 20 To Measure Length 21 To Perform Hub Blink 23 Interpreting cable Test Results 24 Battery Replacement 29 Specifications 30 Ac...

Page 5: ...ife of the RJ45 jack of the TestifierPRO Contacts should always be recessed into the plastic grooves of the plug Features Two line by 16 character full alphanumeric LCD with icons for clear results De...

Page 6: ...plays PASS icon for correctly wired 6 pin telephone cables both straight through reversed Map ID feature provides a cost effective way to identify ID up to 20 cable runs at a time Length measurement i...

Page 7: ...F connector for Telco Network and Coax cables It has an integrated remote bay that houses a detachable test remote for patch cable testing The test remote has built in jacks for Telco and Network cabl...

Page 8: ...ted for that mode Pressing the Power button momentarily for less than 2 seconds toggles the EL backlight Pressing the Power button for more than 2 seconds turns off the unit When the unit is off press...

Page 9: ...Key Description Key Feature Description Telco mode button Coax mode button Network mode button Up and down buttons SEL Select button SETUP Setup mode button Power button...

Page 10: ...pin numbers of the remote normally being the same as the top line for a normal straight thru data cable If there is a miswire the numbers on the second line indicate the pin numbers detected If no co...

Page 11: ...there are both shorts and high R Faults only messages for the shorts are cycled through The ID icon will have a number directly below it indicating the remote ID number If there is no remote the Test...

Page 12: ...will display the PASS icon when all 6 pins are correctly wired in a one to one order If all 6 pins are correctly wired in the reverse order the PASS icon along with a flashing Rev icon will be display...

Page 13: ...function identifies multiple Telco Coax or Network cables by displaying ID numbers of the map only remotes attached to the far end of the cables It is a cost effective way to identify up to 20 cable...

Page 14: ...djustable capacitance per unit length the length constant to calculate the cable length The TestifierPRO supports three user adjustable length constants one for each type of cables The TestifierPRO re...

Page 15: ...to select mode the TestifierPRO automatically selects a pair without a fault Users can adjust the length constant using the up and down arrows The CAL icon is displayed when the TestifierPRO recalcula...

Page 16: ...he Tone icon and the icon for the connector assumed to be used Once in the tone generator mode use the up and down buttons to step to the next connector pin s drive option When the SEL button is press...

Page 17: ...ns to scroll through settable options Use the SEL button to change the current setting to the alternate option Press any mode key or the Power key to exit Setup mode and save the updated parameters Th...

Page 18: ...holding the SETUP key and pressing the NETWORK button powers up the unit in diagnostic mode Step 1 of diagnostic mode displays the revision of the firmware being used Step 2 activates all elements of...

Page 19: ...status continuously when it is powered on When the battery low icon is activated battery voltage has dropped to below 6 4V The battery should be replaced as soon as practical Below 6 0V the LCD displa...

Page 20: ...map ID or length measurement 70 minutes while executing tone trace or hub blink Be sure to install a battery if using the TestifierPRO for the first time see battery installation TestifierPRO LCD Dis...

Page 21: ...liding it out of the remote bay at the bottom of the main unit Plug the other end of cable into the remote unit 3 Press the mode button Telco Coax or Network for the type of cable being tested If not...

Page 22: ...If not already in Cable Test mode press the corresponding mode button repeatedly until Cable Test is displayed then press the SEL button to execute cable test 3 Results should appear within 5 seconds...

Page 23: ...he type of cable being tested If not already in Cable Test mode press the corresponding mode button repeatedly until Cable Test is displayed and then press the SEL button to execute cable test The Tes...

Page 24: ...apped to the main unit Insert a map only remote to the jack at the far end of the cable 3 A PASS icon and the ID number for the map only ID will be displayed The type of cable Telco Coax or Network be...

Page 25: ...an be obtained by having only one wire of a twisted pair carrying the tone Selecting a single pin instead of a pair will achieve this 4 To turn tone off press any of the three mode buttons To Measure...

Page 26: ...attery is installed the default length constants are initialized to 15 pF foot for Network cable 22 5 pF foot for Coax cable and 17 5 pF foot for Telco cable For Network cable most Cat 5 Cat 5e Cat 6...

Page 27: ...sed to measure the length of the unknown cable for the same model and from the same manufacturer Fifty feet or more is suggested to minimize the resolution error 1 foot in 50 is 2 of uncertainty To Pe...

Page 28: ...d uplink crossover cable In Telephone mode the Reversed Pin message will be displayed if all connected pins are in reverse order and the PASS icon will also be displayed if all 6 connections are prese...

Page 29: ...if the shield is shorted to a pin Miswire A wire or both wires of a pair are not connected to the correct pins at the other end of the cable The wire map shows the pin numbers from line 1 main to lin...

Page 30: ...A cable can be wired with correct continuity but not with correct pairing This most often happens when the cable is terminated consistently at both ends but in the wrong order A dynamic or AC test is...

Page 31: ...s the second line will have flashing R in 3 or 4 positions corresponding to the two pairs For a shielded cable if a soft short is detected between the shield and a single pin the second line will have...

Page 32: ...7 7 7 7 7 7 7 7 7 7 8 8 8 8 8 8 8 8 8 8 SHORT T568A B Passing Cable unshielded 1 not twisted with 2 3 not twisted with 6 12345678S ID 12345678S ID 12345678 ID 12345678S ID 12345678S ID 345678S 1 12345...

Page 33: ...tery into the battery compartment and close the battery door 6 Replace the battery door screw using the screw driver Do not over tighten When installing a new battery disconnect any cables connected t...

Page 34: ...cm 1 3 x 2 6 x 6 2 inches Including F connector 3 3 x 6 7 x 16 8 cm 1 3 x 2 6 x 6 6 inches Weight 235 3 grams 8 3 oz with battery and remote Environmental Operating temperature 0 to 50 O C 32 to 122 O...

Page 35: ...years Cable Testing 80 hours with backlight off Cable Types Shielded or unshielded Cat 5E Cat 5 Cat 4 Cat 3 and Coax Minimum cable length for testing for split pairs 0 91 meter 3 feet Minimum cable le...

Page 36: ...1 to 20 RJ11 Plug Mapping Remote TP608 Set of 7 numbered Full remotes TP20 7 5 cable assembly with no fault 6 position plugs reverse pinned Use to map and test 2 4 or 6 pin telephone wiring Can be use...

Page 37: ...peration of this device be assumed by JDSU WEEE Directive Compliance JDSU has established processes in compliance with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC This prod...

Page 38: ...reseller whose name or logo is marked on the equipment then the owner should return the equipment directly to the reseller Instructions for returning waste equipment to JDSU can be found in the Envir...

Page 39: ...which must be clearly marked on the shipping label 2 Ship the equipment with a copy of the sales receipt if available 3 Attach a description of the operational problem 4 Include a contact name phone...

Page 40: ...ales North America Tel 1 805 383 1500 Fax 1 805 383 1595 Latin America Tel 55 11 5503 3800 Fax 55 11 5505 1598 Asia Pacific Tel 852 2892 0990 Fax 852 2892 0770 EMEA Tel 49 7121 86 2222 Fax 49 7121 86...

Reviews: