Chapter 5
Examples
Changing a setup
24
SmartClass E1 Tester Remote Control Reference Guide
Changing a setup
To change a setup
1
Find the setup's name in appendix A.
For example:
E1Bert.Test.Mode
2
Check the setup's applicability and changeability (if you are unsure).
[customer@SCE customer]$ rc s_get_all E1Bert.Test.Mode
2:SCE:cmsend:ack:s_get_all 1,1,1,TERM
3
Query the setup's valid values (if you are unsure).
[customer@SCE customer]$ rc s_get_valid
E1Bert.Test.Mode
2:SCE:cmsend:ack:s_get_valid TERM,MON,BRIDGE,LINELB
4
Change the setup's value.
[customer@SCE customer]$ rc s_set E1Bert.Test.Mode TERM
2:SCE:cmsend:ack:s_set
Querying a result
To query a result
1
Find the result's name in Appendix C.
For example:
E1Bert.0.BertRx.BitErrors
2
Query the result's value, applicability and readiness (if you are unsure).
[customer@SCE customer]$ rc pr_get_all E1Bert.0.BertRx.
BitErrors
2:SCE:cmsend:ack:pr_get_all 1,1,"MAJOR","IN_RANGE",
16566879,201
3
Query the result's value.
[customer@SCE customer]$ rc pr_get E1Bert.0.BertRx.
BitErrors
2:SCE:cmsend:ack:pr_get 0
Executing an action
To execute actions
1
Start a BER test
E1Bert.0.Auto.Auto
(frame and pattern auto configure)
rc a_execute E1Bert.0.Auto.Auto
2
To insert TSE errors
a
To insert one test error
rc s_set E1Bert.0.BertTx.ErrorInsertionType SINGLE
rc a_execute E1Bert.0.BertTx.ErrorInsert
Summary of Contents for SmartClass E1
Page 1: ...SmartClass E1 Tester Remote Control Reference Guide...
Page 2: ......
Page 3: ...SmartClass E1 Tester Remote Control Reference Guide...
Page 6: ...iv SmartClass E1 Tester Remote Control Reference Guide...
Page 14: ...About this Guide Conventions iv SmartClass E1 Tester Remote Control Reference Guide...
Page 40: ...Chapter 5 Examples Executing an action 26 SmartClass E1 Tester Remote Control Reference Guide...
Page 52: ...Appendix A Setups E1 Pulse Shape Setups 38 SmartClass E1 Tester Remote Control Reference Guide...
Page 87: ......