22 Installation and Physical Interface
1. The GND (shield) signal lines should be connected to the common ground.
2. The pins should not be used during SKB operation, unless the power pins (listed in the table below) are
NOT connected.
44
Attention
Active low attention signal, open collector, pulled UP at master with
470 Ohms
45-50
NC
No connect
Table 4: Pin Assignment: Power using the 4x1 Power Connector
PIN
SIGNAL
DESCRIPTION
1
NC
No connect
2
DGND
Digital ground
3
NC
No connect
4
+5V DC
+5 VDC power input
Table 5: Pin Assignment: Power using the Power Pins on the 25x2 IDE Connector
PIN
SIGNAL
DESCRIPTION
13
GND
Shield
14
DGND
Digital ground, RESERVED FOR SK EMULATION/ Power on 2x25
31
GND
Shield
32
DGND
Digital ground, RESERVED FOR SK EMULATION/ Power on 2x25
33
+5 VDC
RESERVED FOR SK EMULATION/ Power on 2x25
35
+5 VDC
RESERVED FOR SK EMULATION/ Power on 2x25
36
+5 VDC
RESERVED FOR SK EMULATION/ Power on 2x25
Table 3: Pin Assignment: Enhanced Parallel Interface (on 25x2 IDE connector) (Continued)
Summary of Contents for SKB Series
Page 1: ...SKB SERIES FIBEROPTIC SWITCH MODULE User Manual ...
Page 2: ...ii 10109002 Rev 001 August 2001 2001 JDS Uniphase All rights reserved ...
Page 4: ...iv ...
Page 11: ...7 Contents ...
Page 13: ...9 List of Figures ...
Page 15: ...11 List of Tables ...
Page 19: ...4 Safety Information Instructions and Symbols ...
Page 25: ...10 Introduction ...
Page 53: ...38 Operation and Control Instructions ...
Page 91: ...76 Commands ...
Page 111: ...96 Application Notes ...
Page 113: ...98 Service ...