Chapter 7 Automated RFC 2544 Testing
About the Throughput test
HST-3000 Ethernet Testing User’s Guide
199
Uplink and downlink results can then be observed on the
master tester.
Combined - If you indicate that you want to run a combined
test, an upstream test is performed, followed by a downstream
test. Results can be observed on the master tester.
About the Throughput test
The throughput test is used to determine the highest possible
bandwidth at which no frames are lost.
You now have the option to use the Standard RFC zeroing-in
method for the throughput test (which is required when testing
a half duplex link) or the new Enhanced JDSU zeroing-in
method.
Standard RFC
method
The Standard RFC zeroing-in method functions as follows:
Attempting Phase
For each frame length you select, beginning at the maximum
test bandwidth you specified, the HST determines whether the
number of transmitted frames carrying an Acterna payload is
Figure 38
Asymmetrical RFC test