Chapter 4
DS1 Test Commands
Considerations for SLC-96 testing
CT-650 Command-Line Reference Guide
Release 9.4
51
– DS0 testing of SLC-96 circuits is accomplished using either ESF
or D4 TAD framing.
– DS0 drop and insert VF or DDS is supported on SLC-96 circuits.
– SLC-96 Datalink is not supported.
– SLC-96 Signaling is not supported.
– Only DS1 in-band loopcodes are supported on SLC-96 framed
circuits.
– Any DTU with the default framing is set to
SLC
will
not
be allocated
for FT1 testing.
– If a CT-650 has both DTUs and DT1s, you must select SLC
framing in the
Monitor
command. This enables the CT-650 to
allocate the DTU for the test.