Appendix C
Test Patterns and Loop Codes
Loop codes
208
CT-650 Command-Line Reference Guide
Release 9.4
CSU <ft1_chan>
<0-8_rptrs>
b
Selects DS0A latching Customer Service Unit loop codes for specified
channel. Include number of repeaters between the test head and CSU/
Repeater. This loopcode will loop CSUs and Repeaters.
OCU <ft1_chan>
Selects DS0A latching Office Channel Unit loop codes for specified
channel.
V.54 <ft1_chan>|All
Selects latching V.54 loop codes for specified channel. If All is
selected, the V.54 loopcode is transmitted across all channels of the
fractional bandwidth.
a. For looping HDSL HTU-R, HTU-C, and Doublers, also transmits an arming code of 11000 and a disarming code
of 11100.
b. The CSU and OCU commands send DDS DS0A loopcodes, not the inband DS1 codes (smart jack).
Table 24
Loop codes (Continued)
Code