![JDS Uniphase CellAdvisor JD780A Series User Manual Download Page 96](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616096.webp)
JD780A Series Analyzers
96
Using Interference Analyzer
3.
To change the mode, press the
MEASURE
hot key and then select the measurement mode:
Spectrogram
,
Dual Spectrogram
,
RSSI
,
Interference Finder
,
Spectrum Replayer
, or
Radar
Chart
.
NOTE
If the
Dual Spectrogram
is selected, you can select the left or right measurement pane
in
MEASURE SETUP
to configure measurement parameters for the selected
spectrogram.
Configuring test parameters
Setting frequency
You need to set the frequency range to be measured either with the center frequency and span or with
the start and stop frequencies. You can also set the frequency with the channel number and span.
Procedure
To set the center frequency and span:
1.
Press the
FREQ/DIST
hard key.
2.
Toggle the
Unit
soft key and select
Freq
.
3.
Press the
Center Frequency
soft key.
4.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow keys.
5.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
6.
Press the
Span
soft key, and then do one of the following:
–
To set the span manually, select
Span
, enter a value, and then select the unit.
–
To set the span automatically, select
Full Span
,
Zero Span
, or
Last Span
as needed.
NOTE
The
Zero Span
option is available only in the Spectrum mode. If you have selected
Zero
Span
, select
TRIGGER
> Free Run
,
External
,
GPS
,
Video
, or
Display Position
.
To set the start and stop frequencies:
1.
Press the
FREQ/DIST
hard key.
2.
Toggle the
Unit
soft key and select
Freq
.
3.
Press the
Start Frequency
soft key.
4.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow keys.
5.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
6.
Press the
Stop Frequency
soft key.
7.
Enter a value by using the numeric keys. You can also use the rotary knob or the arrow keys.
8.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
To set the channel number and span:
1.
Press the
FREQ/DIST
hard key.
2.
Toggle the
Unit
soft key and select
Channel
.
3.
To select the standard channel, complete the following steps:
a.
Press the
Channel Std
soft key. The standard channel window appears.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......