Technical data
Frequency
869,50 MHz
Power supply
12/24V ac/dc (9-35V dc / 8-28V ac)
Consumption standby/operating
18mA/80mA
Memory
6 transmitters (3 on relay 1, 3 on relay 2)
Relay numbers
2 relays
Relay contacts
1A
Radiated power
< 1mW
Operating temperature
-20ºC - +85ºC
Seal
IP54 (with IP65 cable glands)
Box size
82 x 190 x 40mm
Range
50m
Starting up
Mechanical installation
Fix the back of the box to the wall, using the wall plugs and screws supplied. Install the receiver, close to the door and avoid metal
surfaces between the receiver and the transmitter. Pass the cables through the bottom of the receiver. Connect the power cables to
the terminals of the printed circuit, following the indications of the connections diagram. Store the transmitter on the receiver. Fix
the front of the receiver to the back with the screws supplied for the purpose.
Programming the transmitter on the receiver
While programming the receiver, press the PROG button on the transmitter to be programmed into the receiver.
The receiver allows programming 6 transmitters (3 for Relay 1 and 3 for Relay 2).
Each safety edge transmitter must be learnt into the appropriate channel of the safety edge receiver.