Electric lock or suction cups
The relays can switch up to 2A of resistive loads. The number of manoeuvres depends on the type and characteristics of the
loads.
With resistive loads, they can reach 1000000 manoeuvres with 30W loads.
DC inductive loads: 30W / 30Vdc / 1A -> 500000 manoeuvres. One diode (1N4007) along with the electric lock or suction
cups is necessary in parallel.
Example relay connection 1:
AC inductive loads: 30Va / 30Vac / 1A -> 750000 manoeuvres. A varistor (V68ZA2) with electric lock or suction cups is
necessary in parallel.
Example relay connection 1:
If using suction cups, the relay type
must be "Normally closed" (see: "Con-
figuring relays and assigning traffic
schedules").
The diode or varistor must be connected
as close as possible to the electric lock
or suction cup.