background image

Convection Preheater

Ref. PHBE-A

INSTRUCTION MANUAL

www.jbctools.com

Summary of Contents for PHBE-A

Page 1: ...Convection Preheater Ref PHBE A INSTRUCTION MANUAL www jbctools com...

Page 2: ...14 100V 120V 0009401 230V Thermocouple 1 unit Ref PH218 Kapton Tape 1 unit Ref PH217 Manual 1 unit Ref 0023518 Ref PHBE A Convection Preheater Heater Unit Console Convection Preheater 1 unit Ref PHBE...

Page 3: ...tion Preheater Support Heater Unit Console 2 8 Color TFT screen Start Stop USB B connector Zone B Zone A RJ45 connector to Heater Unit USB A connector Foot for vertical set up Push the button to fold...

Page 4: ...05 Thermocouple selected temp and mode Control Protection Info General Work mode Profile editor Reset Graphics Files Press INFO for each parameter description Available languages English Spanish Germa...

Page 5: ...les from the Work mode menu to set them up The thermocouples TC can work in three diferent ways depending on what is needed Control the unit mantains the selected temperature Protection the Heater Uni...

Page 6: ...heating process will be the same as long as the same working conditions are respected The profiles which already have the data from the Teach profile are marked with this symbol These profiles can be...

Page 7: ...m is the number of steps 2 3 or 4 The thicker your PCB is and the more layers it contains the more steps are needed to obtain a gradual warming These profiles are not modifiable but can be used as a t...

Page 8: ...ssing Graphics in the main MENU temperature of TC1 thermocouple and power figures in real time are displayed 17 14 Temperature Power Ext Temp C 50 100 150 200 250 300 Power Graphics Switch Y axis betw...

Page 9: ...USB flash drive into the USB A connector to export import profiles Update the station software 1 Download the JBC Update File from www jbctools com software html and save it on a USB flash drive Pref...

Page 10: ...are is reached the Heater Unit will stop the process and a warning message will be shown 3 IPC does not recommend exceeding ramp up rates over 3 4 C sec 5 7 F sec so as to reduce the risk of thermal s...

Page 11: ...Alcohol can only be used to clean the metal parts Only if it is absolutely necessary and if cleaning with isopropyl alcohol IPA is not enough itisrecommendedtouseascraper to remove dirt in the glass a...

Page 12: ...nite Heat can cause inflamable products to ignite even when out of sight Be careful with the remains of liquid tin In contact with skin it can cause burns Avoid flux coming into contact with skin or e...

Page 13: ...ater Unit 426 x 444 x 41 mm 16 8 x 17 5 x 1 6 in Maximum Power 1800W 1800W 1400W Heating Area 180 x 277 mm 7 1 x 10 9 in 1 zone 360 x 277 mm 14 2 x 10 9 in 2 zones Temperature Range 50 250 C 120 482 F...

Page 14: ...Notes 14...

Page 15: ...15 www jbctools com...

Page 16: ...warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be...

Reviews: